Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
Fabric OS Message Reference 37
53-1001767-01
Chapter
3
AN System Messages
AN-1001
Message <timestamp>, [AN-1001], <sequence-number>,, ERROR, <system-name>, Failed to
allocate memory: <function name>
Probable Cause Indicates that the specified function has failed to allocate memory.
Recommended
Action
Check memory usage on the switch using the memShow command. Restart or power cycle the
switch.
Severity ERROR
AN-1002
Message <timestamp>, [AN-1002], <sequence-number>,, ERROR, <system-name>, Failed to
initialize; rc = <error>
Probable Cause Indicates that the initialization of the 'trafd' daemon has failed.
Recommended
Action
Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS
Command Reference Manual for more information on this command.
Severity ERROR
AN-1003
Message <timestamp>, [AN-1003], <sequence-number>,, WARNING, <system-name>, Latency
bottleneck at slot <slot number>, port <port number within slot number>.
<percentage of seconds affected by latency bottlenecking>.2f percent of last
<observation period over which the percentage of affected seconds is reported>
seconds were affected. Avg. inter-frame time <observed frame rate>.4f us.
Probable Cause For an F_Port, it indicates that the attached device is slow in responding to frames going out of this
port. This latency may be inherent in the device or due to heavy workload on the device. For an
E_Port, it indicates a downstream primary bottleneck.
Recommended
Action
Find the Top Talkers in the egress direction from this port and apply Ingress Rate Limiting to one or
more of them.
Severity WARNING