Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
Fabric OS Message Reference 53
53-1001767-01
Chapter
5
ANV System Messages
ANV-1001
Message <timestamp>, [ANV-1001], <sequence-number>,, ERROR, <system-name>, Port <port
number> port fault. Please change the SFP or check cable.
Probable Cause Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, or a faulty
cable between peer ports.
Recommended
Action
Verify if you are using compatible SFPs on the peer ports. Verify if the SFPs have deteriorated and if
the Fibre Channel cable is faulty. Replace the SFPs or the cable if necessary.
Severity ERROR
ANV-1002
Message <timestamp>, [ANV-1002], <sequence-number>,Ffdc, ERROR, <system-name>, Port <port
number> chip faulted due to internal error.
Probable Cause Indicates an internal error. All the ports on the blade or switch will be disrupted.
Recommended
Action
For a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade to recover
the system. For a non-bladed system, perform the fastBoot command on the switch to recover the
system.
Severity ERROR
ANV-1003
Message <timestamp>, [ANV-1003], <sequence-number>,, CRITICAL, <system-name>, <slot
number>,<chip index>: HW ASIC Chip error. Type = 0x<chip error type>, Error =
<chip error string>..
Probable Cause Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may
degrade data traffic.
Recommended
Action
Restart the system at the next maintenance window. If the problem persists, replace the blade.
Severity CRITICAL