Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)
Table Of Contents
- Contents
- About This Document
- Introduction To System Messages
- RASLog Messages
- AG System Messages
- AN System Messages
- AUTH System Messages
- ANV System Messages
- BKSW System Messages
- BL System Messages
- BLL System Messages
- BLS System Messages
- BM System Messages
- C2 System Messages
- CDR System Messages
- CEE CONFIG System Messages
- CER System Messages
- CHASSIS System Messages
- CNM System Messages
- CONF System Messages
- CTAP System Messages
- CVLC System Messages
- CVLM System Messages
- DAUTH System Messages
- EM System Messages
- ESS System Messages
- ESWCH System Messages
- EVMD System Messages
- FABR System Messages
- FABS System Messages
- FBC System Messages
- FCMC System Messages
- FCIP System Messages
- FCOE System Messages
- FCPD System Messages
- FCPH System Messages
- FCR System Messages
- FICON System Messages
- FICU System Messages
- FKLB System Messages
- FLOD System Messages
- FSPF System Messages
- FSS System Messages
- FSSM System Messages
- FW System Messages
- HAM System Messages
- HAMK System Messages
- HIL System Messages
- HLO System Messages
- HMON System Messages
- HSL System Messages
- HTTP System Messages
- IBD System Messages
- IBPD System Messages
- ICPD System Messages
- IPAD System Messages
- IPS System Messages
- ISCS System Messages
- ISNS System Messages
- KAC System Messages
- KSWD System Messages
- KTRC System Messages
- L2SYS System Messages
- LACP System Messages
- LANCE System Messages
- LFM System Messages
- LOG System Messages
- LSDB System Messages
- MFIC System Messages
- MPTH System Messages
- MQ System Messages
- MS System Messages
- MSTP System Messages
- NBFS System Messages
- NS System Messages
- NSM System Messages
- ONM System Messages
- PDM System Messages
- PDTR System Messages
- PLAT System Messages
- PMGR System Messages
- PORT System Messages
- PS System Messages
- PSWP System Messages
- RAS System Messages
- RCS System Messages
- RKD System Messages
- RMOND System Messages
- RPCD System Messages
- RTWR System Messages
- SAS System Messages
- SCN System Messages
- SEC System Messages
- SFLOW System Messages
- SNMP System Messages
- SPC System Messages
- SPM System Messages
- SS System Messages
- SSM System Messages
- SULB System Messages
- SWCH System Messages
- SYSC System Messages
- SYSM System Messages
- TAPE System Messages
- TRCE System Messages
- TRCK System Messages
- TS System Messages
- UCST System Messages
- UPTH System Messages
- WEBD System Messages
- XTUN System Messages
- ZEUS System Messages
- ZOLB System Messages
- ZONE System Messages
- Audit Log Messages
- AUDIT AG System Messages
- AUDIT AN System Messages
- AUDIT AUTH System Messages
- AUDIT BLS System Messages
- AUDIT CNM System Messages
- AUDIT CONF System Messages
- AUDIT CVLM System Messages
- AUDIT FCIP System Messages
- AUDIT FICU System Messages
- AUDIT FW System Messages
- AUDIT HTTP System Messages
- AUDIT IPAD System Messages
- AUDIT PORT System Messages
- AUDIT SEC System Messages
- AUDIT SNMP System Messages
- AUDIT SPM System Messages
- AUDIT SULB System Messages
- AUDIT SWCH System Messages
- AUDIT UCST System Messages
- AUDIT ZONE System Messages
Fabric OS Message Reference 69
53-1001767-01
BL-1030
7
BL-1030
Message <timestamp>, [BL-1030], <sequence-number>,, INFO, <system-name>, All GigE/FCIP
Virtualization/FC Fastwrite ports on the switch will be reset as part of the
firmware upgrade.
Probable Cause Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be
upgraded and resulted in the cold upgrade. As part of the upgrade, all the GbE or Fibre Channel
over IP (FCIP) or Virtualization data elements or FC Fastwrite ports were reset.
Recommended
Action
No action is required.
Severity INFO
BL-1031
Message <timestamp>, [BL-1031], <sequence-number>,, CRITICAL, <system-name>, Link timeout
in internal port (slot <Slot number>, port <Port number>) resulted in blade fault.
Use slotpoweroff/slotpoweron to recover the blade.
Probable Cause Indicates that link timeout occurred in one of the backend internal ports.
Recommended
Action
Power cycle the blade or run the slotPowerOff and slotPowerOn commands.
Severity CRITICAL
BL-1032
Message <timestamp>, [BL-1032], <sequence-number>,, CRITICAL, <system-name>, (slot <slot
number>,bitmap 0x<object control flags(bitmap)>) ports never came up ONLINE
(reason <reason for port disable>, state <status of the blade>). Disabling slot.
Probable Cause Indicates that back-end (non-user) ports have not come ONLINE within time limit.
Recommended
Action
Restart or power cycle the blade. Run the systemVerification command to verify that the blade does
not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST)
is enabled. If the message persists, replace the blade.
Refer to the Fabric OS Command Reference for more information on the systemVerification
command.
Severity CRITICAL
BL-1033
Message <timestamp>, [BL-1033], <sequence-number>,, CRITICAL, <system-name>, (slot <slot
number>,bitmap 0x<object control flags(bitmap)>) No disable acknowledgment from
ports (state <status of the blade>). Disabling slot.