Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
70 Fabric OS Message Reference
53-1001767-01
BL-1034
7
Probable Cause Indicates that the system has timed out while waiting for disable messages from the user ports
after disabling the ports.
Recommended
Action
Restart or power cycle the blade. Run the systemVerification command to verify that the blade does
not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST)
is enabled. If the message persists, replace the blade.
Refer to the Fabric OS Command Reference for more information on the systemVerification
command.
Severity CRITICAL
BL-1034
Message <timestamp>, [BL-1034], <sequence-number>,, INFO, <system-name>, Slot <slot
number>
FC Initialization completed.
Probable Cause Indicates that the slot has completed initializing Fibre Channel (FC) ports.
Recommended
Action
No action is required.
Severity INFO
BL-1035
Message <timestamp>, [BL-1035], <sequence-number>,, INFO, <system-name>, Slot <slot
number> iSCSI port <iscsi port number> Initialization completed.
Probable Cause Indicates that the slot has completed initializing the specified iSCSI port.
Recommended
Action
No action is required.
Severity INFO
BL-1036
Message <timestamp>, [BL-1036], <sequence-number>,, CRITICAL, <system-name>, Faulting 8G
blade in slot = <slot number> due to incompatible stag mode. All EX/VEX ports must
be disabled in order to enable the 8G blade in the chassis.
Probable Cause Indicates that the FOS 6.0, 8G blade with legacy mode (EX_port having stag) will be disabled.
Recommended
Action
Disable all EX/VEX ports and perform a slotpoweroff or slotpoweron operation on the 8G blade.
Also, all EX/VEX ports can be re-enabled now.
Severity CRITICAL