Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
Fabric OS Message Reference 131
53-1001767-01
CVLC-1030
19
Recommended
Action
Break the mirror and re-establish the mirror after rekey on primary LUN is complete.
Severity WARNING
CVLC-1030
Message <timestamp>, [CVLC-1030], <sequence-number>,, WARNING, <system-name>, Primary LUN
may be out of sync with mirror LUN.\nContainer: <Target container name>,
Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.
Probable Cause Indicates the manual rekey was completed on primary LUN.
Recommended
Action
1. Make the target ports of the mirror LUN offline to hosts.
2. Re-establish the mirror.
3. Once the mirror is in sync, split the mirror.
4. Bring back the target ports of the mirror LUN online.
Severity WARNING
CVLC-1031
Message <timestamp>, [CVLC-1031], <sequence-number>,, WARNING, <system-name>, Primary LUN
is restored from mirror LUN. LUN in read-only mode.\nContainer: <Target container
name>, Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.
Probable Cause Indicates a rekeyed primary LUN may have been restored from mirror LUN without synchronizing.
Recommended
Action
1. Create a new primary LUN.
2. Add it to its container with -newLUN option.
3. Using host based migration application, copy data from old to new primary LUN.
Severity WARNING
CVLC-1032
Message <timestamp>, [CVLC-1032], <sequence-number>,, INFO, <system-name>, Secondary
metadata for LUN has been restored.\nContainer: <Target container name>,
Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.
Probable Cause Indicates the host I/Os to secondary metadata region.
Recommended
Action
No action is required.
Severity INFO