Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
Fabric OS Message Reference 133
53-1001767-01
Chapter
20
CVLM System Messages
CVLM-1001
Message <timestamp>, [CVLM-1001], <sequence-number>,, ERROR, <system-name>, Failed to
allocate memory: <function name>.
Probable Cause Indicates that the specified function has failed to allocate memory.
Recommended
Action
Check the memory usage on the switch using the memShow command. Restart or power cycle the
switch.
Severity ERROR
CVLM-1002
Message <timestamp>, [CVLM-1002], <sequence-number>,, ERROR, <system-name>, Failed to
initialize <module> rc = <error>.
Probable Cause Indicates that an initialization of a module within the CVLMD has failed.
Recommended
Action
Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS
Command Reference Manual for more information on this command.
Severity ERROR
CVLM-1003
Message <timestamp>, [CVLM-1003], <sequence-number>,, INFO, <system-name>, Crypto device
configuration has been committed by switch <Switch WWN>.
Probable Cause Indicates that the switch has committed a crypto device configuration.
Recommended
Action
No action is required.
Severity INFO
CVLM-1004
Message <timestamp>, [CVLM-1004], <sequence-number>,, WARNING, <system-name>, Crypto
device configuration between local switch <local switch WWN> and peer <peer switch
WWN> is out of sync. New encryption session is not allowed.