Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)
Table Of Contents
- Contents
- About This Document
- Introduction To System Messages
- RASLog Messages
- AG System Messages
- AN System Messages
- AUTH System Messages
- ANV System Messages
- BKSW System Messages
- BL System Messages
- BLL System Messages
- BLS System Messages
- BM System Messages
- C2 System Messages
- CDR System Messages
- CEE CONFIG System Messages
- CER System Messages
- CHASSIS System Messages
- CNM System Messages
- CONF System Messages
- CTAP System Messages
- CVLC System Messages
- CVLM System Messages
- DAUTH System Messages
- EM System Messages
- ESS System Messages
- ESWCH System Messages
- EVMD System Messages
- FABR System Messages
- FABS System Messages
- FBC System Messages
- FCMC System Messages
- FCIP System Messages
- FCOE System Messages
- FCPD System Messages
- FCPH System Messages
- FCR System Messages
- FICON System Messages
- FICU System Messages
- FKLB System Messages
- FLOD System Messages
- FSPF System Messages
- FSS System Messages
- FSSM System Messages
- FW System Messages
- HAM System Messages
- HAMK System Messages
- HIL System Messages
- HLO System Messages
- HMON System Messages
- HSL System Messages
- HTTP System Messages
- IBD System Messages
- IBPD System Messages
- ICPD System Messages
- IPAD System Messages
- IPS System Messages
- ISCS System Messages
- ISNS System Messages
- KAC System Messages
- KSWD System Messages
- KTRC System Messages
- L2SYS System Messages
- LACP System Messages
- LANCE System Messages
- LFM System Messages
- LOG System Messages
- LSDB System Messages
- MFIC System Messages
- MPTH System Messages
- MQ System Messages
- MS System Messages
- MSTP System Messages
- NBFS System Messages
- NS System Messages
- NSM System Messages
- ONM System Messages
- PDM System Messages
- PDTR System Messages
- PLAT System Messages
- PMGR System Messages
- PORT System Messages
- PS System Messages
- PSWP System Messages
- RAS System Messages
- RCS System Messages
- RKD System Messages
- RMOND System Messages
- RPCD System Messages
- RTWR System Messages
- SAS System Messages
- SCN System Messages
- SEC System Messages
- SFLOW System Messages
- SNMP System Messages
- SPC System Messages
- SPM System Messages
- SS System Messages
- SSM System Messages
- SULB System Messages
- SWCH System Messages
- SYSC System Messages
- SYSM System Messages
- TAPE System Messages
- TRCE System Messages
- TRCK System Messages
- TS System Messages
- UCST System Messages
- UPTH System Messages
- WEBD System Messages
- XTUN System Messages
- ZEUS System Messages
- ZOLB System Messages
- ZONE System Messages
- Audit Log Messages
- AUDIT AG System Messages
- AUDIT AN System Messages
- AUDIT AUTH System Messages
- AUDIT BLS System Messages
- AUDIT CNM System Messages
- AUDIT CONF System Messages
- AUDIT CVLM System Messages
- AUDIT FCIP System Messages
- AUDIT FICU System Messages
- AUDIT FW System Messages
- AUDIT HTTP System Messages
- AUDIT IPAD System Messages
- AUDIT PORT System Messages
- AUDIT SEC System Messages
- AUDIT SNMP System Messages
- AUDIT SPM System Messages
- AUDIT SULB System Messages
- AUDIT SWCH System Messages
- AUDIT UCST System Messages
- AUDIT ZONE System Messages
134 Fabric OS Message Reference
53-1001767-01
CVLM-1005
20
Probable Cause Indicates that EE nodes in the cluster encryption group have different configurations.
Recommended
Action
Synchronize the configuration in the cluster group using the cryptocfg --commit command. Refer to
the Fabric OS Command Reference Manual for more information on this command.
Severity WARNING
CVLM-1005
Message <timestamp>, [CVLM-1005], <sequence-number>,, INFO, <system-name>, Crypto service
is <status> on the switch.
Probable Cause Indicates that Crypto service is enabled or disabled on the switch.
Recommended
Action
No action is required.
Severity INFO
CVLM-1006
Message <timestamp>, [CVLM-1006], <sequence-number>,, WARNING, <system-name>, Crypto
device <device WWN> in target container <container name> is not in AD0.
Probable Cause Indicates that the crypto device in the crypto target container is not in AD0.
Recommended
Action
Use the ad command to move the crypto device into AD0. Refer to the Fabric OS Command
Reference Manual for more information on this command.
Severity WARNING
CVLM-1007
Message <timestamp>, [CVLM-1007], <sequence-number>,, WARNING, <system-name>, Redirect
zone update failure. Status is <status>.
Probable Cause Indicates that the redirect zone update has failed.
Recommended
Action
Issue the cryptocfg --commit command again. Refer to the Fabric OS Command Reference Manual
for more information on this command.
Severity WARNING
CVLM-1008
Message <timestamp>, [CVLM-1008], <sequence-number>,, WARNING, <system-name>, The member
<EE node WWN><EE slot num> of HAC <HAC name> is not in the fabric.
Probable Cause Indicates that the member of HAC is not in the fabric.