Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
Fabric OS Message Reference 169
53-1001767-01
Chapter
24
ESWCH System Messages
ESW-1001
Message <timestamp>, [ESW-1001], <sequence-number>,, ERROR, <system-name>, Switch is not
in ready state - Switch enable failed switch status= 0x<switch status>, c_flags =
0x<switch control flags>.
Probable Cause Indicates that the switch enable has failed.
Recommended
Action
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity ERROR
ESW-1002
Message <timestamp>, [ESW-1002], <sequence-number>,, INFO, <system-name>, Security
violation: Unauthorized device <wwn name of device> tries to flogin to port <port
number>.
Probable Cause Indicates that the device is not present in the authorized profile list.
Recommended
Action
Verify that the device is authorized to log in to the switch. If the device is authorized, first run the
secPolicyDump command to verify whether the specified device world wide name (WWN) is listed. If
it is not listed, run the secPolicyAdd command to add this device to an existing policy.
Severity INFO
ESW-1003
Message <timestamp>, [ESW-1003], <sequence-number>,, ERROR, <system-name>, Slot ENABLED
but Not Ready during recovery, disabling slot = <slot number>(<return value>).
Probable Cause Indicates that the slot state has been detected as inconsistent during failover or recovery.
Recommended
Action
On a Brocade 8000 switch, restart or power cycle the switch.
Severity ERROR