Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)
Table Of Contents
- Contents
- About This Document
- Introduction To System Messages
- RASLog Messages
- AG System Messages
- AN System Messages
- AUTH System Messages
- ANV System Messages
- BKSW System Messages
- BL System Messages
- BLL System Messages
- BLS System Messages
- BM System Messages
- C2 System Messages
- CDR System Messages
- CEE CONFIG System Messages
- CER System Messages
- CHASSIS System Messages
- CNM System Messages
- CONF System Messages
- CTAP System Messages
- CVLC System Messages
- CVLM System Messages
- DAUTH System Messages
- EM System Messages
- ESS System Messages
- ESWCH System Messages
- EVMD System Messages
- FABR System Messages
- FABS System Messages
- FBC System Messages
- FCMC System Messages
- FCIP System Messages
- FCOE System Messages
- FCPD System Messages
- FCPH System Messages
- FCR System Messages
- FICON System Messages
- FICU System Messages
- FKLB System Messages
- FLOD System Messages
- FSPF System Messages
- FSS System Messages
- FSSM System Messages
- FW System Messages
- HAM System Messages
- HAMK System Messages
- HIL System Messages
- HLO System Messages
- HMON System Messages
- HSL System Messages
- HTTP System Messages
- IBD System Messages
- IBPD System Messages
- ICPD System Messages
- IPAD System Messages
- IPS System Messages
- ISCS System Messages
- ISNS System Messages
- KAC System Messages
- KSWD System Messages
- KTRC System Messages
- L2SYS System Messages
- LACP System Messages
- LANCE System Messages
- LFM System Messages
- LOG System Messages
- LSDB System Messages
- MFIC System Messages
- MPTH System Messages
- MQ System Messages
- MS System Messages
- MSTP System Messages
- NBFS System Messages
- NS System Messages
- NSM System Messages
- ONM System Messages
- PDM System Messages
- PDTR System Messages
- PLAT System Messages
- PMGR System Messages
- PORT System Messages
- PS System Messages
- PSWP System Messages
- RAS System Messages
- RCS System Messages
- RKD System Messages
- RMOND System Messages
- RPCD System Messages
- RTWR System Messages
- SAS System Messages
- SCN System Messages
- SEC System Messages
- SFLOW System Messages
- SNMP System Messages
- SPC System Messages
- SPM System Messages
- SS System Messages
- SSM System Messages
- SULB System Messages
- SWCH System Messages
- SYSC System Messages
- SYSM System Messages
- TAPE System Messages
- TRCE System Messages
- TRCK System Messages
- TS System Messages
- UCST System Messages
- UPTH System Messages
- WEBD System Messages
- XTUN System Messages
- ZEUS System Messages
- ZOLB System Messages
- ZONE System Messages
- Audit Log Messages
- AUDIT AG System Messages
- AUDIT AN System Messages
- AUDIT AUTH System Messages
- AUDIT BLS System Messages
- AUDIT CNM System Messages
- AUDIT CONF System Messages
- AUDIT CVLM System Messages
- AUDIT FCIP System Messages
- AUDIT FICU System Messages
- AUDIT FW System Messages
- AUDIT HTTP System Messages
- AUDIT IPAD System Messages
- AUDIT PORT System Messages
- AUDIT SEC System Messages
- AUDIT SNMP System Messages
- AUDIT SPM System Messages
- AUDIT SULB System Messages
- AUDIT SWCH System Messages
- AUDIT UCST System Messages
- AUDIT ZONE System Messages
Fabric OS Message Reference 181
53-1001767-01
FABR-1020
26
Probable Cause Indicates that this switch is a value-line switch and has exceeded the limited fabric size: that is, a
specified limit to the number of domains. This limit is defined by your specific value-line license key.
The fabric size has exceeded this specified limit, and the grace period counter has started. If the
grace period is complete and the size of the fabric is still outside the specified limit, Web Tools is
disabled.
Recommended
Action
Bring the fabric size within the licensed limits. Either a full fabric license must be added or the size
of the fabric must be changed to within the licensed limit. Contact your switch provider to obtain a
full fabric license.
Severity CRITICAL
FABR-1020
Message <timestamp>, [FABR-1020], <sequence-number>, FFDC, CRITICAL, <system-name>, Web
Tools will be disabled in <days> days <hours> hours and <minutes> minutes.
Probable Cause Indicates that this switch has a value-line license and has a limited number of domains. If more
than the specified number of domains are in the fabric, a counter is started to disable Web Tools.
This message displays the number of days left in the grace period. After this time, Web Tools is
disabled.
Recommended
Action
Bring the fabric size within the licensed limits. Either a full fabric license must be added or the size
of the fabric must be changed to within the licensed limit. Contact your switch provider to obtain a
full fabric license.
Severity CRITICAL
FABR-1021
Message <timestamp>, [FABR-1021], <sequence-number>, FFDC, CRITICAL, <system-name>, Web
Tools is disabled.
Probable Cause Indicates that this switch has a value-line license and has a limited number of domains. If more
than the specified number of domains are in the fabric, a counter is started to disable Web Tools.
This grace period has expired and Web Tools has been disabled.
Recommended
Action
Bring the fabric size within the licensed limits. Either a full fabric license must be added or the size
of the fabric must be changed to within the licensed limit. Contact your switch provider to obtain a
full fabric license.
Severity CRITICAL
FABR-1022
Message <timestamp>, [FABR-1022], <sequence-number>, FFDC, CRITICAL, <system-name>,
Fabric size (<actual domains>) exceeds supported configuration (<supported
domains>). Fabric limit timer (<type>) started from <grace period in seconds>.