Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
186 Fabric OS Message Reference
53-1001767-01
FABR-1041
26
FABR-1041
Message <timestamp>, [FABR-1041], <sequence-number>, ERROR, <system-name>, Port <Port
that is being disabled> is disabled due to trunk protocol error.
Probable Cause Indicates a link reset was received before the completion of the trunking protocol on the port.
Recommended
Action
Enable the port by running the portEnable command. The port may recover by re-initialization of
the link. If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers followed by the supportSave command and contact your switch service provider.
Severity ERROR
FABR-1043
Message <timestamp>, [FABR-1043], <sequence-number>, ERROR, <system-name>, Detected
Fabric ID conflict with remote (not neighbor) switch <Switchname> (domain <Domain
ID>), FID <Fabric ID>. No local E-ports disabled.
Probable Cause Indicates that the remote switch has a Fabric ID conflict with the local switch. But no ports are
disabled because the remote switch is not adjacent to the local switch.
Recommended
Action
Make sure that all the switches in the fabric have the same Fabric ID or upgrade the switch
firmware to a VF-capable firmware.
Severity ERROR
FABR-1044
Message <timestamp>, [FABR-1044], <sequence-number>, ERROR, <system-name>, Detected
Fabric ID conflict with neighbor switch <Switchname> (domain <Domain ID>), FID
<Fabric ID>. E-ports (<Number of E-ports disabled>) connected to the switch are
disabled.
Probable Cause Indicates that the neighbor switch has a Fabric ID conflict with the local switch. All E_ports directly
connected to the conflicting switch are disabled.
Recommended
Action
Make sure that all the switches in the fabric have the same fabric ID or upgrade the switch
firmware to a VF-capable firmware.
Severity ERROR
FABR-1045
Message <timestamp>, [FABR-1045], <sequence-number>, ERROR, <system-name>, <Text>Detected
Base Switch conflict with remote (not neighbor) switch <Switchname> (domain
<Domain ID>), BS <Base Switch Mode>. No local E-ports disabled.
Probable Cause Indicates that the remote switch has a Base Switch attribute conflict with the local switch. But no
ports are disabled because the remote switch is not adjacent to the local switch.