Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)
Table Of Contents
- Contents
- About This Document
- Introduction To System Messages
- RASLog Messages
- AG System Messages
- AN System Messages
- AUTH System Messages
- ANV System Messages
- BKSW System Messages
- BL System Messages
- BLL System Messages
- BLS System Messages
- BM System Messages
- C2 System Messages
- CDR System Messages
- CEE CONFIG System Messages
- CER System Messages
- CHASSIS System Messages
- CNM System Messages
- CONF System Messages
- CTAP System Messages
- CVLC System Messages
- CVLM System Messages
- DAUTH System Messages
- EM System Messages
- ESS System Messages
- ESWCH System Messages
- EVMD System Messages
- FABR System Messages
- FABS System Messages
- FBC System Messages
- FCMC System Messages
- FCIP System Messages
- FCOE System Messages
- FCPD System Messages
- FCPH System Messages
- FCR System Messages
- FICON System Messages
- FICU System Messages
- FKLB System Messages
- FLOD System Messages
- FSPF System Messages
- FSS System Messages
- FSSM System Messages
- FW System Messages
- HAM System Messages
- HAMK System Messages
- HIL System Messages
- HLO System Messages
- HMON System Messages
- HSL System Messages
- HTTP System Messages
- IBD System Messages
- IBPD System Messages
- ICPD System Messages
- IPAD System Messages
- IPS System Messages
- ISCS System Messages
- ISNS System Messages
- KAC System Messages
- KSWD System Messages
- KTRC System Messages
- L2SYS System Messages
- LACP System Messages
- LANCE System Messages
- LFM System Messages
- LOG System Messages
- LSDB System Messages
- MFIC System Messages
- MPTH System Messages
- MQ System Messages
- MS System Messages
- MSTP System Messages
- NBFS System Messages
- NS System Messages
- NSM System Messages
- ONM System Messages
- PDM System Messages
- PDTR System Messages
- PLAT System Messages
- PMGR System Messages
- PORT System Messages
- PS System Messages
- PSWP System Messages
- RAS System Messages
- RCS System Messages
- RKD System Messages
- RMOND System Messages
- RPCD System Messages
- RTWR System Messages
- SAS System Messages
- SCN System Messages
- SEC System Messages
- SFLOW System Messages
- SNMP System Messages
- SPC System Messages
- SPM System Messages
- SS System Messages
- SSM System Messages
- SULB System Messages
- SWCH System Messages
- SYSC System Messages
- SYSM System Messages
- TAPE System Messages
- TRCE System Messages
- TRCK System Messages
- TS System Messages
- UCST System Messages
- UPTH System Messages
- WEBD System Messages
- XTUN System Messages
- ZEUS System Messages
- ZOLB System Messages
- ZONE System Messages
- Audit Log Messages
- AUDIT AG System Messages
- AUDIT AN System Messages
- AUDIT AUTH System Messages
- AUDIT BLS System Messages
- AUDIT CNM System Messages
- AUDIT CONF System Messages
- AUDIT CVLM System Messages
- AUDIT FCIP System Messages
- AUDIT FICU System Messages
- AUDIT FW System Messages
- AUDIT HTTP System Messages
- AUDIT IPAD System Messages
- AUDIT PORT System Messages
- AUDIT SEC System Messages
- AUDIT SNMP System Messages
- AUDIT SPM System Messages
- AUDIT SULB System Messages
- AUDIT SWCH System Messages
- AUDIT UCST System Messages
- AUDIT ZONE System Messages
186 Fabric OS Message Reference
53-1001767-01
FABR-1041
26
FABR-1041
Message <timestamp>, [FABR-1041], <sequence-number>, ERROR, <system-name>, Port <Port
that is being disabled> is disabled due to trunk protocol error.
Probable Cause Indicates a link reset was received before the completion of the trunking protocol on the port.
Recommended
Action
Enable the port by running the portEnable command. The port may recover by re-initialization of
the link. If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers followed by the supportSave command and contact your switch service provider.
Severity ERROR
FABR-1043
Message <timestamp>, [FABR-1043], <sequence-number>, ERROR, <system-name>, Detected
Fabric ID conflict with remote (not neighbor) switch <Switchname> (domain <Domain
ID>), FID <Fabric ID>. No local E-ports disabled.
Probable Cause Indicates that the remote switch has a Fabric ID conflict with the local switch. But no ports are
disabled because the remote switch is not adjacent to the local switch.
Recommended
Action
Make sure that all the switches in the fabric have the same Fabric ID or upgrade the switch
firmware to a VF-capable firmware.
Severity ERROR
FABR-1044
Message <timestamp>, [FABR-1044], <sequence-number>, ERROR, <system-name>, Detected
Fabric ID conflict with neighbor switch <Switchname> (domain <Domain ID>), FID
<Fabric ID>. E-ports (<Number of E-ports disabled>) connected to the switch are
disabled.
Probable Cause Indicates that the neighbor switch has a Fabric ID conflict with the local switch. All E_ports directly
connected to the conflicting switch are disabled.
Recommended
Action
Make sure that all the switches in the fabric have the same fabric ID or upgrade the switch
firmware to a VF-capable firmware.
Severity ERROR
FABR-1045
Message <timestamp>, [FABR-1045], <sequence-number>, ERROR, <system-name>, <Text>Detected
Base Switch conflict with remote (not neighbor) switch <Switchname> (domain
<Domain ID>), BS <Base Switch Mode>. No local E-ports disabled.
Probable Cause Indicates that the remote switch has a Base Switch attribute conflict with the local switch. But no
ports are disabled because the remote switch is not adjacent to the local switch.