Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
Fabric OS Message Reference 227
53-1001767-01
FCR-1053
34
Recommended
Action
Run the portEnable and portDisable commands to enable and disable the port.
If the problem persists contact your switch service provider.
Severity ERROR
FCR-1053
Message <timestamp>, [FCR-1053], <sequence-number>,, WARNING, <system-name>, Port <port
number> was disabled, <disable reason>.
Probable Cause Indicates that the specified port was disabled because of a mismatched configuration parameter.
Recommended
Action
Use the specified disable reason to identify a possible configuration parameter mismatch between
the EX_Port and the switch at other end of the link.
Severity WARNING
FCR-1054
Message <timestamp>, [FCR-1054], <sequence-number>,, WARNING, <system-name>, Port <port
number> received ILS <command> of incorrect size (<actual payload size>); valid
ILS size is <expected payload size>.
Probable Cause Indicates that an internal link service (ILS) IU of invalid size was received from the switch on the
other end of the link.
Recommended
Action
Check the error message log on the other switch using the errShow command for additional
messages.
Check for a faulty cable or deteriorated small form-factor pluggable (SFP). Replace the cable or SFP
if necessary.
Run the portLogDumpPort command on both the receiving and transmitting port.
Run the fabStateShow command on the transmitting switch.
If the message persists, collect switch information using the supportShow command, and contact
your switch service provider.
Severity WARNING
FCR-1055
Message <timestamp>, [FCR-1055], <sequence-number>,, INFO, <system-name>, Switch with
domain ID
<domain ID> does not support backbone to edge imports.
Probable Cause Indicates that a switch that does not support backbone-to-edge routing was detected in the
backbone. Edge-to-edge routing will work, but backbone-to-edge routing might fail.
Recommended
Action
No action is required if backbone to edge routing is not required. Otherwise replace the switch with
one that supports backbone to edge routing.