Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)
Table Of Contents
- Contents
- About This Document
- Introduction To System Messages
- RASLog Messages
- AG System Messages
- AN System Messages
- AUTH System Messages
- ANV System Messages
- BKSW System Messages
- BL System Messages
- BLL System Messages
- BLS System Messages
- BM System Messages
- C2 System Messages
- CDR System Messages
- CEE CONFIG System Messages
- CER System Messages
- CHASSIS System Messages
- CNM System Messages
- CONF System Messages
- CTAP System Messages
- CVLC System Messages
- CVLM System Messages
- DAUTH System Messages
- EM System Messages
- ESS System Messages
- ESWCH System Messages
- EVMD System Messages
- FABR System Messages
- FABS System Messages
- FBC System Messages
- FCMC System Messages
- FCIP System Messages
- FCOE System Messages
- FCPD System Messages
- FCPH System Messages
- FCR System Messages
- FICON System Messages
- FICU System Messages
- FKLB System Messages
- FLOD System Messages
- FSPF System Messages
- FSS System Messages
- FSSM System Messages
- FW System Messages
- HAM System Messages
- HAMK System Messages
- HIL System Messages
- HLO System Messages
- HMON System Messages
- HSL System Messages
- HTTP System Messages
- IBD System Messages
- IBPD System Messages
- ICPD System Messages
- IPAD System Messages
- IPS System Messages
- ISCS System Messages
- ISNS System Messages
- KAC System Messages
- KSWD System Messages
- KTRC System Messages
- L2SYS System Messages
- LACP System Messages
- LANCE System Messages
- LFM System Messages
- LOG System Messages
- LSDB System Messages
- MFIC System Messages
- MPTH System Messages
- MQ System Messages
- MS System Messages
- MSTP System Messages
- NBFS System Messages
- NS System Messages
- NSM System Messages
- ONM System Messages
- PDM System Messages
- PDTR System Messages
- PLAT System Messages
- PMGR System Messages
- PORT System Messages
- PS System Messages
- PSWP System Messages
- RAS System Messages
- RCS System Messages
- RKD System Messages
- RMOND System Messages
- RPCD System Messages
- RTWR System Messages
- SAS System Messages
- SCN System Messages
- SEC System Messages
- SFLOW System Messages
- SNMP System Messages
- SPC System Messages
- SPM System Messages
- SS System Messages
- SSM System Messages
- SULB System Messages
- SWCH System Messages
- SYSC System Messages
- SYSM System Messages
- TAPE System Messages
- TRCE System Messages
- TRCK System Messages
- TS System Messages
- UCST System Messages
- UPTH System Messages
- WEBD System Messages
- XTUN System Messages
- ZEUS System Messages
- ZOLB System Messages
- ZONE System Messages
- Audit Log Messages
- AUDIT AG System Messages
- AUDIT AN System Messages
- AUDIT AUTH System Messages
- AUDIT BLS System Messages
- AUDIT CNM System Messages
- AUDIT CONF System Messages
- AUDIT CVLM System Messages
- AUDIT FCIP System Messages
- AUDIT FICU System Messages
- AUDIT FW System Messages
- AUDIT HTTP System Messages
- AUDIT IPAD System Messages
- AUDIT PORT System Messages
- AUDIT SEC System Messages
- AUDIT SNMP System Messages
- AUDIT SPM System Messages
- AUDIT SULB System Messages
- AUDIT SWCH System Messages
- AUDIT UCST System Messages
- AUDIT ZONE System Messages
Fabric OS Message Reference 231
53-1001767-01
FCR-1066
34
FCR-1066
Message <timestamp>, [FCR-1066], <sequence-number>,, ERROR, <system-name>, Fabric on port
<port number> has the same fabric ID as another fabric.
Probable Cause Indicates that either the fabric split, or there is another fabric (possibly the backbone) that has the
same fabric ID as the fabric connected to the specified port.
Recommended
Action
If the fabric split, then merge the fabrics and manually re-enable the port.
If there is another fabric with the same ID, change the fabric ID for the port using the portCfgExport
or portCfgVExport commands.
Severity ERROR
FCR-1067
Message <timestamp>, [FCR-1067], <sequence-number>,, WARNING, <system-name>, Zone
configurations, total LSAN zones and aliases, exceeded on port <port number> by
<overflow> entries; max entries: <LSAN zone limit>.
Probable Cause Indicates that the total number of zone configurations created in the connected fabric exceeds the
maximum number supported by the Fibre Channel.
The limit includes both active and configured information that is part of the zoning database in the
edge fabric. Non-LSAN zones are not counted in the limit.
Recommended
Action
Limit the logical storage area network (LSAN) zoning related zone configuration in the edge fabric
connected to this port.
Severity WARNING
FCR-1068
Message <timestamp>, [FCR-1068], <sequence-number>,, INFO, <system-name>, The FC Routing
service is disabled.
Probable Cause Indicates that the FC Routing service is disabled. This is caused by fosConfig –-disable fcr,
configDefault, or a configDownload with the fcrState set to 2 (disabled). Note that the FC Routing
service is disabled by the factory.
Recommended
Action
No action is required.
Severity INFO
FCR-1069
Message <timestamp>, [FCR-1069], <sequence-number>,, INFO, <system-name>, The FC Routing
service is enabled.