Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)
Table Of Contents
- Contents
- About This Document
- Introduction To System Messages
- RASLog Messages
- AG System Messages
- AN System Messages
- AUTH System Messages
- ANV System Messages
- BKSW System Messages
- BL System Messages
- BLL System Messages
- BLS System Messages
- BM System Messages
- C2 System Messages
- CDR System Messages
- CEE CONFIG System Messages
- CER System Messages
- CHASSIS System Messages
- CNM System Messages
- CONF System Messages
- CTAP System Messages
- CVLC System Messages
- CVLM System Messages
- DAUTH System Messages
- EM System Messages
- ESS System Messages
- ESWCH System Messages
- EVMD System Messages
- FABR System Messages
- FABS System Messages
- FBC System Messages
- FCMC System Messages
- FCIP System Messages
- FCOE System Messages
- FCPD System Messages
- FCPH System Messages
- FCR System Messages
- FICON System Messages
- FICU System Messages
- FKLB System Messages
- FLOD System Messages
- FSPF System Messages
- FSS System Messages
- FSSM System Messages
- FW System Messages
- HAM System Messages
- HAMK System Messages
- HIL System Messages
- HLO System Messages
- HMON System Messages
- HSL System Messages
- HTTP System Messages
- IBD System Messages
- IBPD System Messages
- ICPD System Messages
- IPAD System Messages
- IPS System Messages
- ISCS System Messages
- ISNS System Messages
- KAC System Messages
- KSWD System Messages
- KTRC System Messages
- L2SYS System Messages
- LACP System Messages
- LANCE System Messages
- LFM System Messages
- LOG System Messages
- LSDB System Messages
- MFIC System Messages
- MPTH System Messages
- MQ System Messages
- MS System Messages
- MSTP System Messages
- NBFS System Messages
- NS System Messages
- NSM System Messages
- ONM System Messages
- PDM System Messages
- PDTR System Messages
- PLAT System Messages
- PMGR System Messages
- PORT System Messages
- PS System Messages
- PSWP System Messages
- RAS System Messages
- RCS System Messages
- RKD System Messages
- RMOND System Messages
- RPCD System Messages
- RTWR System Messages
- SAS System Messages
- SCN System Messages
- SEC System Messages
- SFLOW System Messages
- SNMP System Messages
- SPC System Messages
- SPM System Messages
- SS System Messages
- SSM System Messages
- SULB System Messages
- SWCH System Messages
- SYSC System Messages
- SYSM System Messages
- TAPE System Messages
- TRCE System Messages
- TRCK System Messages
- TS System Messages
- UCST System Messages
- UPTH System Messages
- WEBD System Messages
- XTUN System Messages
- ZEUS System Messages
- ZOLB System Messages
- ZONE System Messages
- Audit Log Messages
- AUDIT AG System Messages
- AUDIT AN System Messages
- AUDIT AUTH System Messages
- AUDIT BLS System Messages
- AUDIT CNM System Messages
- AUDIT CONF System Messages
- AUDIT CVLM System Messages
- AUDIT FCIP System Messages
- AUDIT FICU System Messages
- AUDIT FW System Messages
- AUDIT HTTP System Messages
- AUDIT IPAD System Messages
- AUDIT PORT System Messages
- AUDIT SEC System Messages
- AUDIT SNMP System Messages
- AUDIT SPM System Messages
- AUDIT SULB System Messages
- AUDIT SWCH System Messages
- AUDIT UCST System Messages
- AUDIT ZONE System Messages
Fabric OS Message Reference 241
53-1001767-01
FICN-1007
35
FICN-1007
Message <timestamp>, [FICN-1007], <sequence-number>,, ERROR, <system-name>,
DevDiskEgr:FICON Selective Reset:Path=<VEPortNumber HostDomain HostPort
DeviceDomain> <DevicePort LPAR CUADDR DeviceAddr> State=0x<current Emulation
State> stat_array=0x<last 4 Status values that were received from the device>.
Probable Cause Indicates a Selective Reset from the channel was received as either a normal part of path recovery
or starting sequence in an error case.
Recommended
Action
If there was a job failure associated with this event, please contact your vendor's customer support.
Severity ERROR
FICN-1008
Message <timestamp>, [FICN-1008], <sequence-number>,, ERROR, <system-name>,
DevDiskEgr:FICON Purge Path received Path=<VEPortNumber HostDomain HostPort
DeviceDomcontactain> <DevicePort LPAR CUADDR DeviceAddr>.
Probable Cause Indicates a FICON Purge Path was received from the channel as a part of path recovery.
Recommended
Action
If there was a job failure associated with this event, please contact your vendor's customer support
for assistance.
Severity ERROR
FICN-1009
Message <timestamp>, [FICN-1009], <sequence-number>,, INFO, <system-name>,
DevIng:CmdReject Sense Data rcvd:Path=<VEPortNumber HostDomain HostPort
DeviceDomain> <DevicePort LPAR CUADDR DeviceAddr> <Current Emulation State>
LastCmds=<the Last 4 commands issued to the device> Sense Data:Bytes0-0xB=<bytes
0-3 of sense data from the device> <bytes 4-7 of sense data from the device>
<bytes 8-0x0b of sense data from the device>.
Probable Cause Indicates a Unit Check status was received from a device and a sense command was issued to
read the sense data.
Recommended
Action
If there was a job failure associated with this event, please contact your vendor's customer support
for assistance.
Severity INFO
FICN-1010
Message <timestamp>, [FICN-1010], <sequence-number>,, INFO, <system-name>,
DevDiskEgr:Device level exception flag found for Path=<VEPortNumber HostDomain
HostPort DeviceDomain>8X<DevicePort LPAR CUADDR DeviceAddr>8X: Oxid=0x<The OXID
that was reported in the Device Level Exception Frame>4X.