Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)
Table Of Contents
- Contents
- About This Document
- Introduction To System Messages
- RASLog Messages
- AG System Messages
- AN System Messages
- AUTH System Messages
- ANV System Messages
- BKSW System Messages
- BL System Messages
- BLL System Messages
- BLS System Messages
- BM System Messages
- C2 System Messages
- CDR System Messages
- CEE CONFIG System Messages
- CER System Messages
- CHASSIS System Messages
- CNM System Messages
- CONF System Messages
- CTAP System Messages
- CVLC System Messages
- CVLM System Messages
- DAUTH System Messages
- EM System Messages
- ESS System Messages
- ESWCH System Messages
- EVMD System Messages
- FABR System Messages
- FABS System Messages
- FBC System Messages
- FCMC System Messages
- FCIP System Messages
- FCOE System Messages
- FCPD System Messages
- FCPH System Messages
- FCR System Messages
- FICON System Messages
- FICU System Messages
- FKLB System Messages
- FLOD System Messages
- FSPF System Messages
- FSS System Messages
- FSSM System Messages
- FW System Messages
- HAM System Messages
- HAMK System Messages
- HIL System Messages
- HLO System Messages
- HMON System Messages
- HSL System Messages
- HTTP System Messages
- IBD System Messages
- IBPD System Messages
- ICPD System Messages
- IPAD System Messages
- IPS System Messages
- ISCS System Messages
- ISNS System Messages
- KAC System Messages
- KSWD System Messages
- KTRC System Messages
- L2SYS System Messages
- LACP System Messages
- LANCE System Messages
- LFM System Messages
- LOG System Messages
- LSDB System Messages
- MFIC System Messages
- MPTH System Messages
- MQ System Messages
- MS System Messages
- MSTP System Messages
- NBFS System Messages
- NS System Messages
- NSM System Messages
- ONM System Messages
- PDM System Messages
- PDTR System Messages
- PLAT System Messages
- PMGR System Messages
- PORT System Messages
- PS System Messages
- PSWP System Messages
- RAS System Messages
- RCS System Messages
- RKD System Messages
- RMOND System Messages
- RPCD System Messages
- RTWR System Messages
- SAS System Messages
- SCN System Messages
- SEC System Messages
- SFLOW System Messages
- SNMP System Messages
- SPC System Messages
- SPM System Messages
- SS System Messages
- SSM System Messages
- SULB System Messages
- SWCH System Messages
- SYSC System Messages
- SYSM System Messages
- TAPE System Messages
- TRCE System Messages
- TRCK System Messages
- TS System Messages
- UCST System Messages
- UPTH System Messages
- WEBD System Messages
- XTUN System Messages
- ZEUS System Messages
- ZOLB System Messages
- ZONE System Messages
- Audit Log Messages
- AUDIT AG System Messages
- AUDIT AN System Messages
- AUDIT AUTH System Messages
- AUDIT BLS System Messages
- AUDIT CNM System Messages
- AUDIT CONF System Messages
- AUDIT CVLM System Messages
- AUDIT FCIP System Messages
- AUDIT FICU System Messages
- AUDIT FW System Messages
- AUDIT HTTP System Messages
- AUDIT IPAD System Messages
- AUDIT PORT System Messages
- AUDIT SEC System Messages
- AUDIT SNMP System Messages
- AUDIT SPM System Messages
- AUDIT SULB System Messages
- AUDIT SWCH System Messages
- AUDIT UCST System Messages
- AUDIT ZONE System Messages
246 Fabric OS Message Reference
53-1001767-01
FICN-1024
35
FICN-1024
Message <timestamp>, [FICN-1024], <sequence-number>,, ERROR, <system-name>,
DevTapeEgr:FICON Purge received Path=<VEPortNumber HostDomain HostPort
DeviceDomain> <DevicePort LPAR CUADDR DeviceAddr>.
Probable Cause Indicates the FICON channel issued a Purge Path command sequence for a device.
Recommended
Action
If there was an unexpected job failure or IO Error associated with this event, contact your vendor's
customer support for assistance.
Severity ERROR
FICN-1025
Message <timestamp>, [FICN-1025], <sequence-number>,, ERROR, <system-name>,
DevTapeIng:Auto Sense Data received on Path=0x<VEPortNumber HostDomain HostPort
DeviceDomain>8X<DevicePort LPAR CUADDR DeviceAddr>8X Bytes0-0xB=0x<bytes 0-3 of
sense data from the device>8X<bytes 4-7 of sense data from the device>8X<bytes
8-0x0b of sense data from the device>8X.
Probable Cause Indicates the FICON tape write pipelining processed sense data from a FICON device.
Recommended
Action
If there was an unexpected job failure or IO Error associated with this event, contact your vendor's
customer support for assistance.
Severity ERROR
FICN-1026
Message <timestamp>, [FICN-1026], <sequence-number>,, INFO, <system-name>,
DevTapeIng:UnusualStatus:WriteCancelSelr:Generating Final Ending Status
Path=<VEPortNumber HostDomain HostPort DeviceDomain> <DevicePort LPAR CUADDR
DeviceAddr>.
Probable Cause Indicates the FICON tape write pipeline is completing an emulated Selective Reset sequence.
Recommended
Action
If there was an unexpected job failure or IO Error associated with this event, contact your vendor's
customer support for assistance.
Severity INFO
FICN-1027
Message <timestamp>, [FICN-1027], <sequence-number>,, ERROR, <system-name>,
DevTapeIng:Device level exception found for Path=<VEPortNumber HostDomain
HostPort DeviceDomain><DevicePort LPAR CUADDR DeviceAddr>: Oxid=0x<The OXID of
the frame that included the Device Level Exception>.
Probable Cause Indicates an active emulation device delivered a Device Level Exception frame to the emulation
processing.