Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
Fabric OS Message Reference 259
53-1001767-01
FICN-1070
35
Recommended
Action
If resolution of the configuration issue cannot be completed, contact your vendor's customer
support for assistance.
Severity ERROR
FICN-1070
Message <timestamp>, [FICN-1070], <sequence-number>,, INFO, <system-name>,
DevTapeIngr:Exceptional Status rcvd on Path=<VEPortNumber HostDomain HostPort
DeviceDomain> <DevicePort LPAR CUADDR DeviceAddr> state=0x<current emulation
state> status=0x<the exceptional status value>.
Probable Cause Indicates the normal end of tape status (0x0D or 0x05) is received from the device or error status
(including Unit Check 0x02) is received from an active emulation device.
Recommended
Action
The end of tape is a normal event during pipelining and not the unit check. If there are associated
IO error messages with this event, please contact your vendor's customer support for assistance.
Severity INFO
FICN-1071
Message <timestamp>, [FICN-1071], <sequence-number>,, INFO, <system-name>,
HostTapeIngr:Tape Loaded on Path=<VEPortNumber HostDomain HostPort DeviceDomain>
<DevicePort LPAR CUADDR DeviceAddr>.
Probable Cause Indicates the tape IOs are processed from a locally connected LPAR, which indicates that a tape is
loaded on a device.
Recommended
Action
No action is required.
Severity INFO
FICN-1072
Message <timestamp>, [FICN-1072], <sequence-number>,, INFO, <system-name>,
DevTapeEgr:Tape Loaded on Path=<VEPortNumber HostDomain HostPort DeviceDomain>
<DevicePort LPAR CUADDR DeviceAddr>.
Probable Cause Indicates the tape IOs are processed from a locally connected LPAR, which indicates that a tape is
loaded on a device.
Recommended
Action
No action is required.
Severity INFO