Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
Fabric OS Message Reference 263
53-1001767-01
FICN-1082
35
Recommended
Action
This is normally an unexpected event, contact your vendor's customer support for assistance.
Severity WARNING
FICN-1082
Message <timestamp>, [FICN-1082], <sequence-number>,, WARNING, <system-name>,
EmulEls:CSWR_RSCN received on GEPort=<GEPortNumber> VEPort=<VEPortNumber>
Domain=0x<Domain Port Host> Port=0x<Device Side>.
Probable Cause Indicates an attached port which had a FICON emulated path established has logged out from the
switch.
Recommended
Action
This may be an unexpected event, contact your vendor's customer support for assistance.
Severity WARNING
FICN-1083
Message <timestamp>, [FICN-1083], <sequence-number>,, WARNING, <system-name>,
EmulEls:SW_RSCN received on GEPort=<GEPortNumber> VEPort=<VEPortNumber>
Domain=0x<Domain Port Host> Port=0x<Device Side>.
Probable Cause Indicates an attached port with the established FICON emulated path has logged out from the
switch.
Recommended
Action
This may be an unexpected event, contact your vendor's customer support for assistance.
Severity WARNING
FICN-1084
Message <timestamp>, [FICN-1084], <sequence-number>,, ERROR, <system-name>, fcFicInit: No
DRAM2 memory available, FICON emulation is disabled.
Probable Cause Indicates a faulty DRAM2 was detected and access to its address range is prohibited.
Recommended
Action
This is an unexpected event, contact your vendor's customer support for assistance.
Severity ERROR
FICN-1085
Message <timestamp>, [FICN-1085], <sequence-number>,, INFO, <system-name>, FICON FCIP
Tunnel is Up on GE<Either GE0 or GE1>,tunnel Id=<The configured tunnel ID (0-7)>.