FLOD-1001
Message <timestamp>, [FLOD-1001], <sequence-number>, FFDC, WARNING, <system-name>,
Unknown LSR type: port <port number>, type <LSR header type>
Probable Cause Indicates that the link state record (LSR) type is unknown. The following two LSR header types are
the only known types: 1 - Unicast and 3 - Multicast.
Recommended
Action
No action is required because the record is discarded.
Severity WARNING
FLOD-1003
Message <timestamp>, [FLOD-1003], <sequence-number>,, WARNING, <system-name>, Link count
exceeded in received LSR, value = <link count number>
Probable Cause Indicates that the acceptable link count has exceeded in the received link state record (LSR).
Recommended
Action
No action is required because the record is discarded.
Severity WARNING
FLOD-1004
Message <timestamp>, [FLOD-1004], <sequence-number>, FFDC, ERROR, <system-name>,
Excessive LSU length = <LSU length>
Probable Cause Indicates that the LSU size exceeds what the system can support.
Recommended
Action
Reduce the number of switches in the fabric or reduce the number of redundant ISLs between two
switches.
Severity ERROR
FLOD-1005
Message <timestamp>, [FLOD-1005], <sequence-number>,, WARNING, <system-name>, Invalid
received domain ID: <domain number>