If the message persists, run the supportFtp (as needed) to set up automatic FTP transfers; then run
the supportSave command and contact your switch service provider.
Severity WARNING
FSS-1004
Message <timestamp>, [FSS-1004], <sequence-number>, SLOT cp-slot-number | CHASSIS, ERROR,
<system-name>, Memory shortage
Probable Cause Indicates that the system ran out of memory.
Recommended
Action
Run the memShow command to view memory usage.
Run the haSyncStart command if this is a dual-CP system, or reboot the switch if it is a nonbladed
system.
If the message persists, run the supportFtp (as needed) to set up automatic FTP transfers; then run
the supportSave command and contact your switch service provider.
Severity ERROR
FSS-1005
Message <timestamp>, [FSS-1005], <sequence-number>, SLOT cp-slot-number | CHASSIS,
WARNING, <system-name>, FSS read failure
Probable Cause Indicates that the read system call to the Fabric OS state synchronization (FSS) device failed.
Recommended
Action
If the message persists, run the supportFtp (as needed) to set up automatic FTP transfers; then run
the supportSave command and contact your switch service provider.
Severity WARNING
FSS-1006
Message <timestamp>, [FSS-1006], <sequence-number>, SLOT cp-slot-number | CHASSIS,
WARNING, <system-name>, No FSS message available
Probable Cause Indicates that data is not available on the Fabric OS state synchronization (FSS) device.
Recommended
Action
If the message persists, run the supportFtp (as needed) to set up automatic FTP transfers; then run
the supportSave command and contact your switch service provider.
Severity WARNING
FSS-1007
Message <timestamp>, [FSS-1007], <sequence-number>, SLOT cp-slot-number | CHASSIS,
CRITICAL, <system-name>,
<component name>: Faulty Ethernet connection.