Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
310 Fabric OS Message Reference
53-1001767-01
FW-1177
42
FW-1177
Message <timestamp>, [FW-1177], <sequence-number>,, INFO, <system-name>, <Port Name>,
<Label>, is below low boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Probable Cause Indicates that the number of invalid words that the port experiences has fallen below the low
boundary. Invalid words usually indicate a hardware problem with an small form-factor pluggable
(SFP) or cable. A low number of invalid words means that the switch is functioning normally.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity INFO
FW-1178
Message <timestamp>, [FW-1178], <sequence-number>,, WARNING, <system-name>, <Port Name>,
<Label>, is above high boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Probable Cause Indicates that the number of invalid words that the port experiences has risen above the high
boundary. Invalid words usually indicate a hardware problem with an small form-factor pluggable
(SFP) or cable.
Recommended
Action
Check both ends of your connections, your SFP, and your cable to verify that none are faulty.
Severity WARNING
FW-1179
Message <timestamp>, [FW-1179], <sequence-number>,, INFO, <system-name>, <Port Name>,
<Label>, is between high and low boundaries(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
Probable Cause Indicates that the number of invalid words that the port experiences has changed from a value
outside of the acceptable range to a value within the acceptable range. Invalid words usually
indicate a hardware problem with an small form-factor pluggable (SFP) or cable.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity INFO
FW-1180
Message <timestamp>, [FW-1180], <sequence-number>,, INFO, <system-name>, <Port Name>,
<Label>, value has changed(High=<High value>, Low=<Low value>). Current value is
<Value> <Unit>.