Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
Fabric OS Message Reference 329
53-1001767-01
FW-1343
42
Recommended
Action
Run the errShow command to determine the IP location of the login attempt. Responses to
security-class messages depend on user policies. Consult your security administrator for response
strategies and policies.
Severity WARNING
FW-1343
Message <timestamp>, [FW-1343], <sequence-number>,, INFO, <system-name>, <Label>, is
between high and low boundaries(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Probable Cause Indicates that the number of login violations has changed from a value outside of the acceptable
range to a value within the acceptable range. Login violations indicate that a login failure has been
detected.
Recommended
Action
No action is required.
Severity INFO
FW-1349
Message <timestamp>, [FW-1349], <sequence-number>,, INFO, <system-name>, <Label>, is
below low boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause Indicates that the number of invalid signatures has fallen below the low boundary. Invalid-signature
violations indicate that a packet with an invalid signature has been received from the primary fabric
configuration server (FCS). When the FCS downloads a new configuration to the other switches in
the fabric, the packet is signed using the private key of the primary FCS. The receiving switch has to
verify this signature with the public key of the primary FCS switch. If verification fails, it rejects the
packet. This counter keeps track of the number of packets received with invalid signatures.
Recommended
Action
No action is required.
Severity INFO
FW-1350
Message <timestamp>, [FW-1350], <sequence-number>,, WARNING, <system-name>, <Label>, is
above high boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.