Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
346 Fabric OS Message Reference
53-1001767-01
FW-1442
42
Severity INFO
FW-1442
Message <timestamp>, [FW-1442], <sequence-number>,, INFO, <system-name>, <FRU label>
state has changed to <FRU state>.
Probable Cause Indicates that the state of the specified field-replaceable unit (FRU) has changed to “on”.
Recommended
Action
No action is required. Verify that the event was planned.
Severity INFO
FW-1443
Message <timestamp>, [FW-1443], <sequence-number>,, INFO, <system-name>, <FRU label>
state has changed to <FRU state>.
Probable Cause Indicates that the state of the specified field-replaceable unit (FRU) changed to “off”.
Recommended
Action
No action is required. Verify that the event was planned.
Severity INFO
FW-1444
Message <timestamp>, [FW-1444], <sequence-number>,, WARNING, <system-name>, <FRU label>
state has changed to <FRU state>.
Probable Cause Indicates that the state of the specified field-replaceable unit (FRU) has changed to “faulty”.
Recommended
Action
Replace the FRU.
Severity WARNING
FW-1445
Message <timestamp>, [FW-1445], <sequence-number>,, INFO, <system-name>, Four power
supplies are now required for 2X redundancy, Switch Status Policy values changed.
Probable Cause Indicates that the switch now requires 4 power supplies and previous Switch Status Policy
parameters will be overwritten to reflect this. The presence of an AP blade means that more than
one power supply may be required to provide adequate power. So (even if the AP blade is powered
down or removed) the Switch Status policy values will now reflect the need for 4 power supplies to
maintain full (2X) redundancy.