Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
Fabric OS Message Reference 369
53-1001767-01
Chapter
45
HIL System Messages
HIL-1101
Message <timestamp>, [HIL-1101], <sequence-number>,, ERROR, <system-name>, Slot <slot
number> faulted, <nominal voltage> (<measured voltage>) is above threshold.
Probable Cause Indicates that the blade voltage is above threshold.
Recommended
Action
Replace the faulty blade or switch (for nonbladed switches).
Severity ERROR
HIL-1102
Message <timestamp>, [HIL-1102], <sequence-number>,, ERROR, <system-name>, Slot <slot
number> faulted, <nominal voltage> (<measured voltage>) is below threshold.
Probable Cause Indicates that the blade voltage is below threshold.
Recommended
Action
Replace the faulty blade or switch (for nonbladed switches).
Severity ERROR
HIL-1103
Message <timestamp>, [HIL-1103], <sequence-number>,, ERROR, <system-name>, Blower <blower
number> faulted, <nominal voltage> (<measured voltage>) is above threshold.
Probable Cause Indicates that the fan voltage is above threshold.
Recommended
Action
Run the psShow command to verify the power supply status.
Try to reseat the faulty fan field-replaceable units (FRUs) and power supply FRU to verify that they
are seated properly.
If the problem persists, replace the fan FRU or the power supply FRU as necessary.
Severity ERROR