Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
376 Fabric OS Message Reference
53-1001767-01
HIL-1309
45
Recommended
Action
Replace the faulty fan field-replaceable units (FRUs) immediately.
Severity ERROR
HIL-1309
Message <timestamp>, [HIL-1309], <sequence-number>,, ERROR, <system-name>, <count> fan
FRUs failed. Replace failed fan FRUs immediately.
Probable Cause Indicates that multiple fans have failed. This message is often preceded by a low fan speed
message.
Recommended
Action
Replace the faulty fan field-replaceable unit (FRU)s immediately.
Severity ERROR
HIL-1310
Message <timestamp>, [HIL-1310], <sequence-number>,, WARNING, <system-name>, <count>
fans faulty.
Probable Cause Indicates that multiple fans have failed. This message is often preceded by a low fan speed
message.
Recommended
Action
Since the fans are not field replaceable, replace the switch if the temperature is high.
Severity WARNING
HIL-1311
Message <timestamp>, [HIL-1311], <sequence-number>,, INFO, <system-name>, No fans are
faulty.
Probable Cause Indicates recovery from earlier condition of one or more fans having failed.
Recommended
Action
This can only occur on switches with non-removable fans. It follows a previous indication of
faultiness.
If the fan continues to generate this message, it indicates oscillation between faulty and non-faulty
behavior. Replace the switch because the fan is not field-replaceable.
Severity INFO
HIL-1401
Message <timestamp>, [HIL-1401], <sequence-number>,, WARNING, <system-name>, One fan FRU
missing. Install fan FRU immediately.