NBFS System Messages
NBFS-1001
Message <timestamp>, [NBFS-1001], <sequence-number>,, INFO, <system-name>, Duplicate
E_Port SCN from port <portnumber> in state <state change name> (<state change
number>)
Probable Cause Indicates a duplicate E_Port State Change Number was reported. The neighbor finite state machine
(NBFSM) states are as follows:
0 - Down
1 - Init
2 - Database Exchange
3 - Database Acknowledge Wait
4 - Database Wait
5 - Full
Recommended
Action
No action is required.
Severity INFO
NBFS-1002
Message <timestamp>, [NBFS-1002], <sequence-number>, FFDC, ERROR, <system-name>, Wrong
input: <state name> to neighbor FSM, state <current state name>, port <portnumber>
Probable Cause Indicates the wrong input was sent to the neighbor finite state machine (NBFSM). NBFSM states
are as follows:
0 - Down
1 - Init
2 - Database Exchange
3 - Database Acknowledge Wait
4 - Database Wait
5 - Full
If this error occurs repeatedly, then there is a problem in the protocol implementation between two
switches.
Recommended
Action
Run the nbrStateShow command to check the neighbor state of the port listed in the message. If it
is FULL, then this message can safely be ignored. Otherwise, run the portDisable and portEnable
commands to refresh the port.