Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
Fabric OS Message Reference 491
53-1001767-01
Chapter
84
RKD System Messages
RKD-1001
Message <timestamp>, [RKD-1001], <sequence-number>,, INFO, <system-name>, <Re-key type
(First time encryption/Rekey/Write Metadata)> operation <Re-key action
(started/completed/cancelled)>.\nTarget: <Target physial WWN>, Initiator:
<Initiator physical WWN>, LUN ID: <LUN ID>.\n SessionId:<Session ID>/<Session MN>
Probable Cause Indicates that a First time encryption/re-key/Write Metadata was started/completed/cancelled.
Recommended
Action
No action is required.
Severity INFO
RKD-1002
Message <timestamp>, [RKD-1002], <sequence-number>,, ERROR, <system-name>, Could not
start <Re-key type (First time encryption/Rekey/Write Metadata)>
operation.\n<I/T/L String>.\n No response from cluster member WWN: <EE WWN> Slot:
<EE Slot Number>.
Probable Cause Indicates that a First time encryption/re-key/Write Metadata was not started.
Recommended
Action
Correct the Cluster Ethernet link error and retry.
Severity ERROR
RKD-1003
Message <timestamp>, [RKD-1003], <sequence-number>,, CRITICAL, <system-name>, <Re-key
type (First time encryption/Rekey/Write Metadata)> encountered a FATAL SCSI error
and will be suspended.\n<I/T/L String>.\nCommand: <Read/Write>\nLBA: <LBA>\nNum
Blocks: <Num of Blocks>\nError: <Error String>\nSK/ASC: <SCSI Sense Key>/<SCSI
ASC>.
Probable Cause Indicates that a First time encryption/re-key/Write Metadata encountered a fatal SCSI error and
was suspended.
Recommended
Action
Correct the error and resume.
Severity CRITICAL