Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)
Table Of Contents
- Contents
- About This Document
- Introduction To System Messages
- RASLog Messages
- AG System Messages
- AN System Messages
- AUTH System Messages
- ANV System Messages
- BKSW System Messages
- BL System Messages
- BLL System Messages
- BLS System Messages
- BM System Messages
- C2 System Messages
- CDR System Messages
- CEE CONFIG System Messages
- CER System Messages
- CHASSIS System Messages
- CNM System Messages
- CONF System Messages
- CTAP System Messages
- CVLC System Messages
- CVLM System Messages
- DAUTH System Messages
- EM System Messages
- ESS System Messages
- ESWCH System Messages
- EVMD System Messages
- FABR System Messages
- FABS System Messages
- FBC System Messages
- FCMC System Messages
- FCIP System Messages
- FCOE System Messages
- FCPD System Messages
- FCPH System Messages
- FCR System Messages
- FICON System Messages
- FICU System Messages
- FKLB System Messages
- FLOD System Messages
- FSPF System Messages
- FSS System Messages
- FSSM System Messages
- FW System Messages
- HAM System Messages
- HAMK System Messages
- HIL System Messages
- HLO System Messages
- HMON System Messages
- HSL System Messages
- HTTP System Messages
- IBD System Messages
- IBPD System Messages
- ICPD System Messages
- IPAD System Messages
- IPS System Messages
- ISCS System Messages
- ISNS System Messages
- KAC System Messages
- KSWD System Messages
- KTRC System Messages
- L2SYS System Messages
- LACP System Messages
- LANCE System Messages
- LFM System Messages
- LOG System Messages
- LSDB System Messages
- MFIC System Messages
- MPTH System Messages
- MQ System Messages
- MS System Messages
- MSTP System Messages
- NBFS System Messages
- NS System Messages
- NSM System Messages
- ONM System Messages
- PDM System Messages
- PDTR System Messages
- PLAT System Messages
- PMGR System Messages
- PORT System Messages
- PS System Messages
- PSWP System Messages
- RAS System Messages
- RCS System Messages
- RKD System Messages
- RMOND System Messages
- RPCD System Messages
- RTWR System Messages
- SAS System Messages
- SCN System Messages
- SEC System Messages
- SFLOW System Messages
- SNMP System Messages
- SPC System Messages
- SPM System Messages
- SS System Messages
- SSM System Messages
- SULB System Messages
- SWCH System Messages
- SYSC System Messages
- SYSM System Messages
- TAPE System Messages
- TRCE System Messages
- TRCK System Messages
- TS System Messages
- UCST System Messages
- UPTH System Messages
- WEBD System Messages
- XTUN System Messages
- ZEUS System Messages
- ZOLB System Messages
- ZONE System Messages
- Audit Log Messages
- AUDIT AG System Messages
- AUDIT AN System Messages
- AUDIT AUTH System Messages
- AUDIT BLS System Messages
- AUDIT CNM System Messages
- AUDIT CONF System Messages
- AUDIT CVLM System Messages
- AUDIT FCIP System Messages
- AUDIT FICU System Messages
- AUDIT FW System Messages
- AUDIT HTTP System Messages
- AUDIT IPAD System Messages
- AUDIT PORT System Messages
- AUDIT SEC System Messages
- AUDIT SNMP System Messages
- AUDIT SPM System Messages
- AUDIT SULB System Messages
- AUDIT SWCH System Messages
- AUDIT UCST System Messages
- AUDIT ZONE System Messages
504 Fabric OS Message Reference
53-1001767-01
SEC-1003
90
SEC-1003
Message <timestamp>, [SEC-1003], <sequence-number>,, WARNING, <system-name>, Fail to
download security data to domain <Domain number> after <Number of retires> retries
Probable Cause Indicates the specified domain has failed to download security data after the specified number of
attempts, and that the failed switch encountered an error accepting the database download. The
primary switch will segment the failed switch after 30 tries.
Recommended
Action
Reset the version stamp on the switch to ‘0’ using the secVersionReset command and then rejoin
the switch to the fabric.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity WARNING
SEC-1005
Message <timestamp>, [SEC-1005], <sequence-number>,, INFO, <system-name>, Primary FCS
receives data request from domain
<Domain number>
Probable Cause Indicates the primary fabric configuration server (FCS) received a data request from the specified
domain. For example, if the switch fails to update the database or is attacked (data injection), a
message is generated to the primary FCS to try to correct and resync with the rest of the switches
in the fabric.
Recommended
Action
Use the secFabricShow command to check whether any of the switches in the fabric encountered
an error. If one or more switches is not in the Ready state, and you have reason to believe that the
error is the result of a possible security breach, take appropriate action as defined by your
enterprise security policy.
Severity INFO
SEC-1006
Message <timestamp>, [SEC-1006], <sequence-number>,, WARNING, <system-name>, Security
statistics error: Failed to reset due to invalid
<data>.
Probable Cause Indicates that invalid data has been received for any statistic-related command for security
(secStatsShow or secStatsReset). The counter is updated automatically when a security violation
occurs. This message might also occur if the updating counter fails.
Recommended
Action
If the message is the result of a user command, retry the statistic command.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WARNING