Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
Fabric OS Message Reference 507
53-1001767-01
SEC-1025
90
SEC-1025
Message <timestamp>, [SEC-1025], <sequence-number>,, ERROR, <system-name>, Invalid IP
address
(<IP address>) detected.
Probable Cause Indicates a corruption occurred during the distribution of the security database. This can occur only
when the primary fabric configuration server (FCS) distributes the security database to the other
switches in the fabric, then local validation finds the error in the security database. This is a rare
occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity ERROR
SEC-1026
Message <timestamp>, [SEC-1026], <sequence-number>,, ERROR, <system-name>, Invalid format
or character in switch member
<switch member ID>.
Probable Cause Indicates a corruption occurred during the distribution of the security database. This can occur only
when the primary fabric configuration server (FCS) distributes the security database to the other
switches in the fabric, then local validation finds the error in the security database. This is a rare
occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity ERROR
SEC-1028
Message <timestamp>, [SEC-1028], <sequence-number>,, ERROR, <system-name>, No name is
specified.
Probable Cause Indicates a corruption occurred during the distribution of the security database. This can occur only
when the primary fabric configuration server (FCS) distributes the security database to the other
switches in the fabric, then local validation finds the error in the security database. This is a rare
occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity ERROR