Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)
Table Of Contents
- Contents
- About This Document
- Introduction To System Messages
- RASLog Messages
- AG System Messages
- AN System Messages
- AUTH System Messages
- ANV System Messages
- BKSW System Messages
- BL System Messages
- BLL System Messages
- BLS System Messages
- BM System Messages
- C2 System Messages
- CDR System Messages
- CEE CONFIG System Messages
- CER System Messages
- CHASSIS System Messages
- CNM System Messages
- CONF System Messages
- CTAP System Messages
- CVLC System Messages
- CVLM System Messages
- DAUTH System Messages
- EM System Messages
- ESS System Messages
- ESWCH System Messages
- EVMD System Messages
- FABR System Messages
- FABS System Messages
- FBC System Messages
- FCMC System Messages
- FCIP System Messages
- FCOE System Messages
- FCPD System Messages
- FCPH System Messages
- FCR System Messages
- FICON System Messages
- FICU System Messages
- FKLB System Messages
- FLOD System Messages
- FSPF System Messages
- FSS System Messages
- FSSM System Messages
- FW System Messages
- HAM System Messages
- HAMK System Messages
- HIL System Messages
- HLO System Messages
- HMON System Messages
- HSL System Messages
- HTTP System Messages
- IBD System Messages
- IBPD System Messages
- ICPD System Messages
- IPAD System Messages
- IPS System Messages
- ISCS System Messages
- ISNS System Messages
- KAC System Messages
- KSWD System Messages
- KTRC System Messages
- L2SYS System Messages
- LACP System Messages
- LANCE System Messages
- LFM System Messages
- LOG System Messages
- LSDB System Messages
- MFIC System Messages
- MPTH System Messages
- MQ System Messages
- MS System Messages
- MSTP System Messages
- NBFS System Messages
- NS System Messages
- NSM System Messages
- ONM System Messages
- PDM System Messages
- PDTR System Messages
- PLAT System Messages
- PMGR System Messages
- PORT System Messages
- PS System Messages
- PSWP System Messages
- RAS System Messages
- RCS System Messages
- RKD System Messages
- RMOND System Messages
- RPCD System Messages
- RTWR System Messages
- SAS System Messages
- SCN System Messages
- SEC System Messages
- SFLOW System Messages
- SNMP System Messages
- SPC System Messages
- SPM System Messages
- SS System Messages
- SSM System Messages
- SULB System Messages
- SWCH System Messages
- SYSC System Messages
- SYSM System Messages
- TAPE System Messages
- TRCE System Messages
- TRCK System Messages
- TS System Messages
- UCST System Messages
- UPTH System Messages
- WEBD System Messages
- XTUN System Messages
- ZEUS System Messages
- ZOLB System Messages
- ZONE System Messages
- Audit Log Messages
- AUDIT AG System Messages
- AUDIT AN System Messages
- AUDIT AUTH System Messages
- AUDIT BLS System Messages
- AUDIT CNM System Messages
- AUDIT CONF System Messages
- AUDIT CVLM System Messages
- AUDIT FCIP System Messages
- AUDIT FICU System Messages
- AUDIT FW System Messages
- AUDIT HTTP System Messages
- AUDIT IPAD System Messages
- AUDIT PORT System Messages
- AUDIT SEC System Messages
- AUDIT SNMP System Messages
- AUDIT SPM System Messages
- AUDIT SULB System Messages
- AUDIT SWCH System Messages
- AUDIT UCST System Messages
- AUDIT ZONE System Messages
526 Fabric OS Message Reference
53-1001767-01
SEC-1104
90
Probable Cause Indicates the switch failed to download a certificate, security database, or policies. This can
happen when the switch does not have enough resources to complete the operation, the fabric has
not stabilized, or the policy database is an invalid format.
Recommended
Action
Wait for fabric to become stable and then retry the operation. If the policy database is in an illegal
format (with configDownload), correct the format and retry the operation.
Severity ERROR
SEC-1104
Message <timestamp>, [SEC-1104], <sequence-number>,, ERROR, <system-name>, Fail to get
primary <Certificate or public key>.
Probable Cause Indicates the switch failed to get either the primary certificate or a primary public key.
Recommended
Action
Verify the primary switch has a valid certificate installed and retry the operation. If a valid
certificate is not installed, install a certificate by following the procedure specified in the Secure
Fabric OS Administrator's Guide.
Severity ERROR
SEC-1105
Message <timestamp>, [SEC-1105], <sequence-number>,, ERROR, <system-name>, Fail to
disable secure mode on all switches.
Probable Cause Indicates the switch failed to disable security in the fabric. This could happen if the switch cannot
get the required resources to complete the command, and sending to a remote domain fails or the
remote domain returns an error.
Recommended
Action
Run the secFabricShow to verify that all switches in the fabric are in the ready state. Retry the
command when all switches are READY.
Severity ERROR
SEC-1106
Message <timestamp>, [SEC-1106], <sequence-number>,, ERROR, <system-name>, Failed to sign
message data.
Probable Cause Indicates that some public key infrastructure (PKI) objects on the switch are not in a valid state,
and a signature operation failed.
Recommended
Action
Run the pkiShow command and verify that all PKI objects exist on the switch. If a failure to validate
PKI objects occurs, follow the steps for re-creating PKI objects outlined in the Secure Fabric OS
Administrator's Guide.
Severity ERROR