Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
578 Fabric OS Message Reference
53-1001767-01
SPC-3010
93
SPC-3010
Message <timestamp>, [SPC-3010], <sequence-number>,, WARNING, <system-name>, <slot number
containing Encryption Engine>, <module name>: SEK integrity failure during
initialization.
Probable Cause Indicates the Crypto Module internal Secret Encryption Key has been corrupted or has not been
initialized.
Recommended
Action
Run the initEE and regEE commands.
Severity ERROR
SPC-3011
Message <timestamp>, [SPC-3011], <sequence-number>,, ERROR, <system-name>, <slot number
containing Encryption Engine>, <module name>: Persistent data storage error: <SP
status code>, KEK: <KEK octet 1> <KEK octet 2> <KEK octet 3> <KEK octet 4>.
Probable Cause Indicates an attempt to store Crypto Module internal data using the Secret Encryption Key failed -
most likely, the EE has been zeroized or tampered with.
Recommended
Action
Run the initEE and regEE commands, then recover or restore the needed primary and secondary
KEKs.
Severity ERROR
SPC-3012
Message <timestamp>, [SPC-3012], <sequence-number>,, ERROR, <system-name>, <slot number
containing Encryption Engine>, <module name>: Persistent data retrieval error: <SP
status code>.
Probable Cause Indicates an attempt to read Crypto Module internal data using the Secret Encryption Key failed -
most likely, the EE has been zeroized or tampered with.
Recommended
Action
Run initEE and regEE commands, then recover or restore the needed primary and secondary KEKs.
Severity ERROR
SPC-3013
Message <timestamp>, [SPC-3013], <sequence-number>,, ERROR, <system-name>, <slot number
containing Encryption Engine>, <module name>: SEK generation failure: <SP status
code>.
Probable Cause Indicates the Crypto Module internal Secret Encryption Key could not be generated.