Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
Fabric OS Message Reference 603
53-1001767-01
SSMD-1217
96
SSMD-1217
Message <timestamp>, [SSMD-1217], <sequence-number>,, WARNING, <system-name>,QoS CEE
could not comply with FCoE scheduler policy for CEE Map <CEE Map name>.
Probable Cause Indicates the DCE System Services Manager (SSM) was unable to translate CEE Map and FCoE
configuration into an ETS scheduler policy implementable by the dataplane ASIC.
Recommended
Action
Redefine CEE Map and FCoE into a configuration that translates into into an ETS scheduler policy
requiring 8 or fewer Traffic Class.
Severity WARNING
SSMD-1300
Message <timestamp>, [SSMD-1300], <sequence-number>,, INFO, <system-name>, CEEMap
<ceemap> is created with precedence <precedence>.
Probable Cause Indicates that a CEEMap is created.
Recommended
Action
No action is required.
Severity INFO
SSMD-1301
Message <timestamp>, [SSMD-1301], <sequence-number>,, INFO, <system-name>, CEEMap
<ceemap> is deleted.
Probable Cause Indicates that a CEEMap is deleted.
Recommended
Action
No action is required.
Severity INFO
SSMD-1302
Message <timestamp>, [SSMD-1302], <sequence-number>,, INFO, <system-name>, CEEMap
<ceemap> priority table <pg_ids> is <action>.
Probable Cause Indicates that PGs added to or removed from existing ceemap.
Recommended
Action
No action is required.
Severity INFO