Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
608 Fabric OS Message Reference
53-1001767-01
SULB-1004
97
SULB-1004
Message <timestamp>, [SULB-1004], INFO, FIRMWARE, <event-initiator-details>,
<event-location>, , Firmwarecommit has completed.
Probable Cause Indicates the FirmwareCommit command is executed.
Recommended
Action
No action is required. Run the firmwareDownloadStatus command for more information.
Severity INFO
SULB-1005
Message <timestamp>, [SULB-1005], <sequence-number>,, INFO, <system-name>, Current Active
CP is preparing to failover.
Probable Cause Indicates the active CP is about to restart. The standby CP is taking over as the active CP.
Recommended
Action
No action is required. The firmwareDownload command is progressing as expected.
Run the firmwareDownloadStatus command for more information.
Severity INFO
SULB-1006
Message <timestamp>, [SULB-1006], <sequence-number>,, INFO, <system-name>, Forced
failover succeeded. New Active CP is running new firmware.
Probable Cause Indicates the previous standby CP has now become the active CP and is running the new firmware
version.
Recommended
Action
No action is required. The firmwareDownload command is progressing as expected.
Run the firmwareDownloadStatus command for more information.
Severity INFO
SULB-1007
Message <timestamp>, [SULB-1007], <sequence-number>,, INFO, <system-name>, Standby CP
reboots.
Probable Cause Indicates the standby CP is rebooting with new firmware.
Recommended
Action
No action is required. The firmwareDownload command is progressing as expected.
Run the firmwareDownloadStatus command for more information.
Severity INFO