SWCH-1001
Message <timestamp>, [SWCH-1001], <sequence-number>,, ERROR, <system-name>, Switch is not
in ready state - Switch enable failed switch status= 0x<switch status>, c_flags =
0x<switch control flags>.
Probable Cause Indicates the switch is enabled before it is ready.
Recommended
Action
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity ERROR
SWCH-1002
Message <timestamp>, [SWCH-1002], <sequence-number>,, INFO, <system-name>, Security
violation: Unauthorized device <wwn name of device> tries to flogin to port <port
number>.
Probable Cause Indicates the device is not present in the authorized profile list.
Recommended
Action
Verify the device is authorized to log in to the switch. If the device is authorized, run the
secPolicyDump command to verify whether the specified device world wide name (WWN) is listed. If
it is not listed, run the secPolicyAdd command to add this device to an existing policy.
Severity INFO
SWCH-1003
Message <timestamp>, [SWCH-1003], <sequence-number>,, ERROR, <system-name>, Slot ENABLED
but Not Ready during recovery, disabling slot = <slot number>(<return value>).
Probable Cause Indicates the slot state has been detected as inconsistent during failover or recovery.
Recommended
Action
On a Brocade 24000 or 48000 switch, run the slotPowerOff command and then the slotPowerOn
command.
On a Brocade 7500 or AP7600 switch, reboot or power cycle the switch.