Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
626 Fabric OS Message Reference
53-1001767-01
SWCH-1011
98
Severity WARNING
SWCH-1011
Message <timestamp>, [SWCH-1011], <sequence-number>,, WARNING, <system-name>, HA state
out of sync: Standby CP (ver = <standby SWC version>) does not support Trunk Area
functionality. (active ver = <active SWC version>, Trunk Area enabled on switch =
<'1' if Trunk Area ports exist; Otherwise '0'>).
Probable Cause Indicates the standby control processor (CP) does not support Trunk Area functionality, but the
switch has some ports with Trunk Area enabled.
Recommended
Action
Load a firmware version on standby that supports Trunk Area functionality, using the
firmwareDownload command.
Severity WARNING
SWCH-1012
Message <timestamp>, [SWCH-1012], <sequence-number>,, INFO, <system-name>, Trunk Area
(<trunk area>) has been enabled for one or more ports).
Probable Cause Indicates that a Trunk Area has been enabled for one or more ports and the configuration file has
been updated.
Recommended
Action
No action is required.
Severity INFO
SWCH-1013
Message <timestamp>, [SWCH-1013], <sequence-number>,, INFO, <system-name>, Trunk Area has
been disabled for one or more ports.
Probable Cause Indicates that a Trunk Area assignment has been disabled for one or more ports and the
configuration file has been updated.
Recommended
Action
No action is required.
Severity INFO
SWCH-1014
Message <timestamp>, [SWCH-1014], <sequence-number>,, INFO, <system-name>, All Trunk
Areas have been disabled.
Probable Cause Indicates that all Trunk Areas have been disabled and the configuration file has been updated.