Fabric OS Message Reference 627
53-1001767-01
SWCH-1015
98
Recommended
Action
No action is required.
Severity INFO
SWCH-1015
Message <timestamp>, [SWCH-1015], <sequence-number>,, WARNING, <system-name>, <Function
name> <Description of problem>.
Probable Cause Indicates that an internal problem has been detected by the software. This is usually an internal
Fabric OS problem or due to file corruption.
Recommended
Action
Restart or power cycle the switch
If the message persists, run the firmwareDownload command to update the firmware.
Severity WARNING
SWCH-1016
Message <timestamp>, [SWCH-1016], <sequence-number>,, INFO, <system-name>, Device <wwn
name of device>fdiscs to port <port number>. Static persistent PID set and area
requested not assigned to the device. Reject FDISC.
Probable Cause Indicates static persistent PID is set and the area requested is not assigned to the device.
Recommended
Action
This is a NPIV device and static peristent PID is set on it, we are not able to assign the area
requested. Remove the static binding to have the device come up with a different area and run the
wwnaddress --unbind wwn command.
Severity INFO
SWCH-1017
Message <timestamp>, [SWCH-1017], <sequence-number>,, INFO, <system-name>, Device <wwn
name of device> tries to flogi to port <port number>, reject FLOGI as persistent
PID is set on the Loop device.
Probable Cause Indicates persistent PID is set and static Persistent PID is not supported on the Loop device.
Recommended
Action
This is a LOOP device and peristent PID is set on it. This is not a supported configuration. Remove
the WWN-PID binding and re-enable the port and then run the wwnaddress --unbind wwn
command.
Severity INFO