Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
Fabric OS Message Reference 663
53-1001767-01
ZONE-1027
111
ZONE-1027
Message <timestamp>, [ZONE-1027], <sequence-number>,, INFO, <system-name>, Zoning
transaction aborted <error reason>. <AD Id>.
Probable Cause Indicates the zoning transaction was aborted due to a variety of potential errors. The error reason
variable can be one of the following:
Zone Merge Received: The fabric is in the process of merging two zone databases.
Zone Config update Received: The fabric is in the process of updating the zone database.
Bad Zone Config: The new config is not viable.
Zoning Operation failed: A zoning operation failed.
Shell exited: The command shell has exited.
Unknown: An error was received for an unknown reason.
User Command: A user aborted the current zoning transaction.
Switch Shutting Down: The switch is currently shutting down.
Recommended
Action
Many of the causes of this error message are transitory, for example, because two administrators
are working with the zoning database concurrently. If you receive this error, wait for few minutes
and try again. Ensure that no user is currently modifying the zone database.
Severity INFO
ZONE-1028
Message <timestamp>, [ZONE-1028], <sequence-number>,, WARNING, <system-name>, Commit zone
DB larger than supported - <zone db size> greater than <max zone db size>.
Probable Cause Indicates the zone database size is greater than the limit allowed by the fabric. The limit of the zone
database size depends on the lowest level switch in the fabric. Older switches have less memory
and force a smaller zone database for the entire fabric.
Recommended
Action
Edit the zone database to keep it within the allowable limit for the specific switches in your fabric.
Refer to the Fabric OS Administrator’s Guide for information on the zone database sizes supported
for each switch.
Severity WARNING
ZONE-1029
Message <timestamp>, [ZONE-1029], <sequence-number>,, WARNING, <system-name>, Restoring
zone cfg from flash failed - bad config saved to <config file name> [<return
code>].
Probable Cause Indicates the zone configuration restored from the flash was faulty.
Recommended
Action
This error will save the faulty zone configuration in the zoned core file directory.