Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)
Table Of Contents
- Contents
- About This Document
- Introduction To System Messages
- RASLog Messages
- AG System Messages
- AN System Messages
- AUTH System Messages
- ANV System Messages
- BKSW System Messages
- BL System Messages
- BLL System Messages
- BLS System Messages
- BM System Messages
- C2 System Messages
- CDR System Messages
- CEE CONFIG System Messages
- CER System Messages
- CHASSIS System Messages
- CNM System Messages
- CONF System Messages
- CTAP System Messages
- CVLC System Messages
- CVLM System Messages
- DAUTH System Messages
- EM System Messages
- ESS System Messages
- ESWCH System Messages
- EVMD System Messages
- FABR System Messages
- FABS System Messages
- FBC System Messages
- FCMC System Messages
- FCIP System Messages
- FCOE System Messages
- FCPD System Messages
- FCPH System Messages
- FCR System Messages
- FICON System Messages
- FICU System Messages
- FKLB System Messages
- FLOD System Messages
- FSPF System Messages
- FSS System Messages
- FSSM System Messages
- FW System Messages
- HAM System Messages
- HAMK System Messages
- HIL System Messages
- HLO System Messages
- HMON System Messages
- HSL System Messages
- HTTP System Messages
- IBD System Messages
- IBPD System Messages
- ICPD System Messages
- IPAD System Messages
- IPS System Messages
- ISCS System Messages
- ISNS System Messages
- KAC System Messages
- KSWD System Messages
- KTRC System Messages
- L2SYS System Messages
- LACP System Messages
- LANCE System Messages
- LFM System Messages
- LOG System Messages
- LSDB System Messages
- MFIC System Messages
- MPTH System Messages
- MQ System Messages
- MS System Messages
- MSTP System Messages
- NBFS System Messages
- NS System Messages
- NSM System Messages
- ONM System Messages
- PDM System Messages
- PDTR System Messages
- PLAT System Messages
- PMGR System Messages
- PORT System Messages
- PS System Messages
- PSWP System Messages
- RAS System Messages
- RCS System Messages
- RKD System Messages
- RMOND System Messages
- RPCD System Messages
- RTWR System Messages
- SAS System Messages
- SCN System Messages
- SEC System Messages
- SFLOW System Messages
- SNMP System Messages
- SPC System Messages
- SPM System Messages
- SS System Messages
- SSM System Messages
- SULB System Messages
- SWCH System Messages
- SYSC System Messages
- SYSM System Messages
- TAPE System Messages
- TRCE System Messages
- TRCK System Messages
- TS System Messages
- UCST System Messages
- UPTH System Messages
- WEBD System Messages
- XTUN System Messages
- ZEUS System Messages
- ZOLB System Messages
- ZONE System Messages
- Audit Log Messages
- AUDIT AG System Messages
- AUDIT AN System Messages
- AUDIT AUTH System Messages
- AUDIT BLS System Messages
- AUDIT CNM System Messages
- AUDIT CONF System Messages
- AUDIT CVLM System Messages
- AUDIT FCIP System Messages
- AUDIT FICU System Messages
- AUDIT FW System Messages
- AUDIT HTTP System Messages
- AUDIT IPAD System Messages
- AUDIT PORT System Messages
- AUDIT SEC System Messages
- AUDIT SNMP System Messages
- AUDIT SPM System Messages
- AUDIT SULB System Messages
- AUDIT SWCH System Messages
- AUDIT UCST System Messages
- AUDIT ZONE System Messages
Fabric OS Message Reference 9
53-1001767-01
Reading a RAS System Message
1
[EM-1031] Message Module
and Message
Number
The message module and number. These values uniquely identify
each message in the Fabric OS and reference the cause and
actions recommended in this manual. Note that not all message
numbers are used; there can be gaps in the numeric message
sequence.
4 Sequence Number The error message position in the log. When a new message is
added to the log, this number is incremented by 1. When this
message reaches the last position in the error log and becomes
the oldest message in the log, it is deleted when a new message is
added.
The message sequence number starts at 1 after a
firmwareDownload and will increase up to a value of
2,147,483,647 (0x7ffffff).
The sequence number will continue to increase beyond the
storage limit of 1024 messages. The sequence number can be
reset to 1 using the errClear command. The sequence number is
persistent across power cycles and switch reboots.
<NULL>
(blank)
Audit and/or
FFDC/SLOT/CHASS
IS/FID Flags
For most messages, this field contains a space character (null
value) indicating that the message is neither an AUDIT or FFDC
message. Messages may contain the following values:
AUDIT indicates that this message is for a security issue.
FFDC indicates that additional first failure data capture
information has also been generated for this event.
FID is the Fabric ID that can range from 0 to 128. FID 128 means
the message was generated by the default switch instance.
CHASSIS is the message that was generated by the chassis
instance.
SLOT number indicates the message was generated from slot #
blade main CPU.
SLOT #/1 indicates the message was generated from slot # blade
Co-CPU.
AUDIT:FFDC indicates that the message is for a security issue and
additional FFDC information has been generated.
ERROR Severity Level The severity of the error:
1 = Critical
2 = Error
3 = Warning
4 = Info
switchname Switch name or
chassis name,
depending on the
action; for example,
high-availability
(HA) messages
typically show the
chassis name, and
login failures show
the logical switch
name.
The defined switch name or the chassis name of the switch. This
value is truncated if it exceeds 16 characters in length. Run either
the chassisName command to name the chassis or the
switchName command to rename the logical switch.
Slot 7 ejector not
closed
Error Description A text string explaining the error encountered and providing
parameters supplied by the software at runtime.
TABLE 3 System Message Field Description (Continued)
Example Variable Name Description