hp StorageWorks director 2/140 rack mount kit installation instructions Part Number: AA-RTDDB-TE/958-000280-001 Second Edition (January 2003) These installation instructions provide the procedures used for installing an HP StorageWorks Director 2/140 in an appropriate rack.
© Hewlett-Packard Company, 2003. All rights reserved. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. This document contains proprietary information, which is protected by copyright.
Contents About this Guide Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv Symbols in Text . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
About this Guide These installation instructions provide information to help you: • Install the HP StorageWorks™ Director 2/140 in an appropriate rack. • Perform the power-on self test. • Contact technical support for additional assistance. Intended Audience This book is intended for use by technicians who are experienced with: • Setting up SAN equipment. • Fibre Channel technology.
About this Guide Document Conventions The conventions included in Table 1 apply. Table 1: Document Conventions Element Convention Cross-reference links Blue text: Figure 1 Key names, menu items, buttons, and dialog box titles Bold File names, application names, and text emphasis Italics User input, command names, system responses (output and messages) Monospace font Variables Monospace, italic font Website addresses Sans serif font (http://thenew.hp.
About this Guide Symbols on Equipment Any enclosed surface or area of the equipment marked with these symbols indicates the presence of electrical shock hazards. Enclosed area contains no operator serviceable parts. WARNING: To reduce the risk of injury from electrical shock hazards, do not open this enclosure. Any RJ-45 receptacle marked with these symbols indicates a network interface connection.
About this Guide Rack Stability WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: • The leveling jacks are extended to the floor. • The full weight of the rack rests on the leveling jacks. • In single rack installations, the stabilizing feet are attached to the rack. • In multiple rack installations, the racks are coupled. • Only one rack component is extended at any time. A rack may become unstable if more than one rack component is extended for any reason.
About this Guide HP Website The HP website has the latest information on this product, as well as the latest drivers. Access storage at: http://thenew.hp.com/country/us/eng/prodserv/storage.html. From this website, select the appropriate product or solution. HP Authorized Reseller For the name of your nearest HP Authorized Reseller: • In the United States, call 1-800-345-1518 • In Canada, call 1-800-263-5868 • Elsewhere, see the HP website for locations and telephone numbers: http://thenew.hp.com.
Installation Instructions This section describes the procedures used for installing a StorageWorks Director 2/140 in an appropriate HP, or comparable, 19-inch Electronic Industries Association (EIA) rack: • HP 9000 series, 10000 series and 11000 series racks • HP rack system/e or 19-inch EIA rack Rack Mount Kit Checklist This section describes the contents of the rack mount kit as well as tools or equipment required to complete the installation.
Installation Instructions Brackets Brackets and rails included in the kit are shown in Figure 1: 1 Two (2) rear mounting brackets 2 Four (4) angle mounting brackets (small) 3 Two (2) shelf brackets 4 Two (2) rear mounting plates 5 Two (2) front mounting brackets 2 4 1 3 5 Figure 1: Brackets included in kit 2 director 2/140 rack mount kit installation instructions
Installation Instructions Required Items Check that the following items are available before beginning the installation. • #2 Phillips screwdriver • Lift device (recommended) Rack Mounting Guidelines This section describes guidelines for installing more than one Director and positioning the Director 2/140 on the lift device. Tips for Installing More than One Switch Review the following tips: • Install the first Director in the lowest position of the rack, allocated for switches.
Installation Instructions Moving the Director 2/140 Use these steps to position the Director 2/140 next to the rack. WARNING: Two people will need to work together to transfer the Director 2/140 to the lift. Make sure the wheels of the lift cannot roll as you transfer the Director 2/140 to the lift. Move the Director 2/140 slowly and carefully onto the lift to prevent back and hand injury. Dropping the Director 2/140 could injure personnel or damage the equipment. 1.
Installation Instructions 3. Use a straight edge to locate the corresponding rack hole along the interior vertical rails of the rack cabinet. Mark this location on each interior vertical rail. 4. Position a small angle bracket along the interior vertical rail as shown in Figure 2. Align the angle bracket so that the two threaded holes on the small tab align with the 1U location marked in step 3. 5. Secure the angle bracket to the rail using two self-tapping sheet metal screws. 6.
Installation Instructions 7. Attach two shelf brackets to the angle brackets on each side of the cabinet using eight pan head screws and a #2 Phillips head screwdriver as shown in Figure 3. NOTE: Center each shelf bracket between the interior vertical rails of the rack cabinet. Figure 3: Shelf brackets mounted in HP 9000, 10000 and 11000 series rack 8. Continue to “Attaching the Mounting Hardware to the Director 2/140” on page 8.
Installation Instructions Installing Shelf Brackets in an HP Rack System/e or 19-inch EIA Rack The shelf brackets mount directly to the interior vertical rails of the HP rack system/e or 19-inch EIA rack using cage nuts and Phillips panhead screws. Use these steps to install the two shelf brackets in an HP rack system/e or 19-inch EIA rack. 1. Determine the appropriate placement for the Director inside the rack. NOTE: HP strongly recommends installing the Director 2/140 in the lowest position in the rack.
Installation Instructions Attaching the Mounting Hardware to the Director 2/140 Use these steps to secure the mounting hardware to the Director 2/140. NOTE: All mounting brackets are attached to the Director 2/140 using 10/32 x 3/8-inch flathead countersunk Phillips screws. 1. Locate the two front mounting brackets in the shipping carton. 2. Secure the front mounting brackets on either side of the Director, as shown in Figure 4. For each front mounting bracket, use three screws. Figure 4: .
Installation Instructions Inserting Cage Nuts in the Rack Before placing the Director into the rack, insert the cage nuts into the appropriate locations along the exterior vertical rack rails. Read the following sections for instructions on inserting front and rear cage nuts in the rack. Inserting the Front Cage Nuts in the Rack Use these steps to insert the six supplied cage nuts in the rack’s front rails. 1. Select one of the exterior vertical rails at the front of the cabinet.
Installation Instructions Installing the Director 2/140 in the Rack Use these steps to maneuver the Director 2/140 into the rack: 1. Using a lift device, position the Director 2/140 at the front of the cabinet. 2. If necessary, adjust the lift height so that the bottom of the Director 2/140 is parallel with the shelf mounts in the rack. 3. Slide the Director along the shelf mounts and into the cabinet until the front mounting brackets on the Director 2/140 contact the front cabinet rails.
Installation Instructions Connecting the Director 2/140 to a Power Source The Director 2/140 includes two power supplies (labeled PS0 and PS1 on the rear of the unit) for redundancy. Each power supply must be connected to an appropriate power source that provides 220-volt AC power.
Installation Instructions Power-On Self Test Once the Director 2/140 is connected to a power source, a Power-On Self Test (POST) is initiated. The following sequence of events occur during the POST: 1. Amber LEDs on both CTP cards and all FPM cards illuminate momentarily. 2. The green LED on each CTP card (active and backup) lights as the card is tested and FPM cards are tested. 3. Green LEDs associated with Fibre Channel ports sequentially illuminate as the ports are tested.