director 2/64 installation guide
B–2 director 2/64 installation guide
Technical Specifications
Environmental Specifications
Figure B–2 lists environmental ranges for shipping, storing, and operating the HP
StorageWorks director 2/64.
Power Requirements
Table B–3 lists director 2/64 power requirements.
Operating Tolerances
Table B–4 lists heating and cooling specifications, shock tolerances, vibration,
acoustical noise and inclination.
Table B–2: Environmental Specifications
Specification Shipping Storage Operating
Weight 76.4 kg (168 lb) 52.3 kg (115 lb) 52.3 kg (115 lb)
Temperature –40°F to 140°F
(40°C to 60 °C)
34°F to 140°F
(1°C to 60 °C)
40°F to 104°F
(4°C to 40 °C)
Humidity 5% to 100% 5% to 80% 8% to 80%
Maximum wet-bulb
temperature
84°F (29°C) 84°F (29°C) 81°F (27°C)
Altitude 40,000 ft
(12,192 km)
40,000 ft
(12,192 km)
10,000 ft
(3,048 km)
Table B–3: Power Requirements
Specification Value
Input voltage 100 to 120 or 200 to 240 VAC
Input frequency 50/60 Hz
Table B–4: Operating Tolerances
Specification Value
Heat dissipation 16 UPM cards (maximum): 490W (1,672 BTU/hr)
Cooling airflow
clearances
Right and left sides: 5.1 cm (2.0 in)
Front and rear: 7.6 cm (3.0 in)
Top and bottom: No clearance required