director 2/64 installation guide

2–8 director 2/64 installation guide
Installing and Configuring the Director 2/64
Install the Director in a Rack
The following sections provide instructions for installing the Director 2/64 in either
the 9000/10000/11000 rack or in the HP rack system/e and industry-standard 19-in
racks. If you plan to install the director in the optional M-Series Rack, consult the hp
StorageWorks m-series rack mount kit installation instructions.
Required Tools
Obtain the following tools:
For a HP rack system/e and industry-standard 19-in rack:
#2 Phillips screwdriver
Torque screwdriver
Table 2–2: Parts for Installing in an HP Rack System/e and Industry-Standard
19-in Rack
Label Item
1 HP StorageWorks Director 2/64 (part number: A6534-62001)
4 Rail Tray Kit (part number: A6534-60016):
One Rail tray
Two mounting brackets
Two M3 Tinnerman nuts
Four Torx T25 16 mm M5 SEM screws
2, 3, 5 Mounting hardware:
Rack mount brackets (part number: A6534-60014) containing:
Two front mounting brackets (5)
Two rear mounting plates (2)
Two rear angle brackets (3)
Switch rack hardware (part number: A6534-62002):
Twenty-two Torx T25 16 mm M5 SEM screws (includes extras)
Eighteen sheet metal nuts
Eight 10-32 Phillips flat-head screws (includes extras)