director 2/64 installation guide

2–54 director 2/64 installation guide
Installing and Configuring the Director 2/64
b. Click the check box in the Write Authorization column to enable or disable
write authorization for the trap recipient (default is disabled). A check mark in
the box indicates write authorization is enabled. When the feature is enabled,
a management workstation user can change the HAFM server’s sysContact,
sysName, and sysLocation SNMP variables.
c. Type the IP address or DNS host name of the trap recipient (SNMP
management workstation) in the associated Trap Recipient field. Use 64 or
fewer alphanumeric characters. Hewlett-Packard recommends using the IP
address.
d. Type a decimal user datagram protocol (UDP) port number in the associated
UDP Port Number field. (This number is commonly 162.)
2. To enable transmission of trap messages to configured SNMP management
workstations, click Enable Authorization Traps. A check mark displays in the
box when transmission is enabled.
3. Click Activate to save the information and close the dialog box.
Configure and Enable E-mail Notification
Use this procedure to configure and enable e-mail addresses and Simple Mail Transfer
Protocol (SMTP) server addresses to receive e-mail notification of director (and other
managed product) events. The addresses must be configured via HAFM, then enabled.
See “Test Remote Notification” on page 2–61.
Use these steps to configure and enable e-mail and SMTP server addresses:
1. Open the Products View page, choose Maintenance > Configure E-Mail. The
Configure E-Mail dialog box displays, as shown in Figure 2–34.