director 2/64 installation guide

2–62 director 2/64 installation guide
Installing and Configuring the Director 2/64
Figure 2–39: Test Remote Notification dialog box
3. Check the Call-Home and E-Mail check boxes.
4. Click Send Test. Call-home and e-mail test messages are transmitted and an
Information dialog box displays.
5. Click OK. Verify that the intended users received the Call-Home and e-mail
notifications.
Configure Threshold Alerts
A threshold alert notifies users when the transmit (Tx) or receive (Rx) throughput
reaches specified values for specific director ports or port types, (E_Ports or F_Ports).
You are notified of a threshold alert by:
A yellow triangle that displays on the port in the Port Card View.
A yellow triangle that displays on the port in the Hardware View.
A yellow triangle that displays in the Alert column of the Port List View.
A yellow triangle that displays by the Threshold Alerts field in the Port
Properties dialog box.
Detailed threshold alert data recorded in the Threshold Alert Log.
Use the Threshold Alerts option on the Configure menu to configure the following:
Name for the alert.
Type of threshold for the alert (Rx, Tx, or either).
Active or inactive state of the alert.
Threshold criteria:
Percent traffic capacity utilized—The percent of the port’s throughput
capacity achieved by the measured throughput. This setting constitutes the
threshold value. For example a value of 50 means that the port’s threshold is
reached when throughput is 50% of capacity.
Time interval during which throughput is measured and alert notification can
occur.