director 2/64 service manual
2–56 director 2/64 service manual
Diagnostics
3
Is fault isolation being performed at the HAFM server?
YES NO
↓ Fault isolation is being performed through the Embedded Web Server
interface. Go to step 25.
4
At the HAFM server’s Products View, does a gray square display at the alert panel
and as the background to the icon representing the director reporting the problem?
YES NO
↓ The director-to-HAFM server connection is restored and is operational. Exit
MAP.
The gray square indicates the HAFM server cannot communicate with the director
because:
• The director-to-HAFM server Ethernet link failed.
• AC power distribution in the director failed, or AC power was disconnected.
• Both of the director’s CTP2 cards failed.
Continue.
5
Ensure the director reporting the problem is connected to facility AC power and the
power switch (circuit breaker) at the rear of the director is set to the ON (up) position.
Inspect the director for indications of being powered on, such as:
Table 2–7: MAP 400: Event Codes
Event Code Explanation Action
430 Excessive Ethernet transmit
errors.
Go to step 8.
431 Excessive Ethernet receive
errors.
Go to step 8.
432 Ethernet adapter reset. Go to step 14.