director 2/64 service manual
director 2/64 service manual 2–57
Diagnostics
• At the front bezel, an illuminated power LED (green) or system error LED
(amber).
• An illuminated green LED on the active CTP2 card, and illuminated green PWR
OK LEDs on both power supplies.
• Audio emanations and airflow from cooling fans.
Is the director powered on?
YES NO
↓ A power distribution problem is indicated. Go to MAP 0100: Power
Distribution Analysis on page 2–34. Exit MAP.
6
At the director, inspect the amber LED at the top of each CTP2 card.
Is the amber LED illuminated on both CTP2 cards?
NO YES
↓ Failure of both CTP2 cards is indicated. Go to MAP 0500: FRU Failure
Analysis on page 2–68. Exit MAP.
7
The director-to-HAFM server Ethernet link failed. Double-click the icon with the gray
square representing the director reporting the problem. The Hardware View displays.
At the Hardware View:
• A gray square displays at the alert panel.
• No FRUs are visible for the director.
• The Director 2/64 Status table is yellow, the Status field displays No Link, and
the Reason field displays an error message.