director 2/64 service manual
director 2/64 service manual 2–63
Diagnostics
3. Power on the maintenance terminal. After the PC powers on, the Windows
desktop displays.
4. Choose Start > Programs > Accessories > HyperTerminal. The Connection
Description dialog box displays.
NOTE: The following steps describe inspecting the IP address using HyperTerminal serial
communication software.
5. Type 64 in the Name field and click OK. The Connect To dialog box displays.
6. Ensure the Connect using field displays COM1 or COM2 (depending on the
serial communication port connection to the director), and click OK. The COMn
Properties dialog box displays (where n is 1 or 2).
7. Configure the Port Settings parameters as follows:
• Bits per second-57600.
• Data bits-8.
• Parity-None.
• Stop bits-1.
• Flow control-Hardware.
When the parameters are set, click OK. The Director 2/64 HyperTerminal
window displays.
8. At the > prompt, type the user-level password (the default is password) and press
the Enter key. The password is case sensitive. The Director 2/64 HyperTerminal
window displays with an C> prompt at the bottom of the window.
9. At the C> prompt, type the ipconfig command and press the Enter key. The
Director 2/64 HyperTerminal window displays with configuration information
listed (including the IP address).
10. Record the director’s IP address.
11. Choose Exit from the File menu to close the HyperTerminal application.
12. Power off the maintenance terminal.
13. Disconnect the RS-232 null modem cable from the director and the maintenance
terminal. Replace the protective cap over the maintenance port.
Continue.