director 2/64 service manual

director 2/64 service manual 2–67
Diagnostics
29
Either a director-to-PC Internet link problem (Internet too busy or IP address typed
incorrectly) or a director Ethernet port failure is indicated.
1. Wait approximately five minutes, then attempt to login to the director again.
2. At the Netsite field (Netscape Navigator) or Address field (Internet Explorer),
type http://xxx.xxx.xxx.xxx, where xxx.xxx.xxx.xxx is the IP address of the
director (obtained in MAP 0000: Start MAP on page 2–12). The Username And
Password Required dialog box displays.
3. Type the user name and password obtained in MAP 0000: Start MAP on page
2–12 and click OK. If the View panel does not display, wait five minutes and
perform this step again.
Is the Embedded Web Server interface operational with the View panel displayed?
NO YES
The director-to-web server PC connection is restored and is operational. Exit
MAP.
Failure of the CTP2 card’s Ethernet port is indicated. Go to MAP 0500: FRU Failure
Analysis on page 2–68. Exit MAP.