director 2/64 service manual

2–68 director 2/64 service manual
Diagnostics
MAP 0500: FRU Failure Analysis
This MAP describes fault isolation for the CTP2 card, SBAR assembly, and fan
module. Failure indicators include:
The amber LED on the FRU illuminates.
The amber emulated LED on a fan graphic at the Hardware View illuminates.
A blinking red and yellow diamond (failed FRU indicator) displays over a FRU
graphic; or a gray square (status unknown indicator) or yellow triangle (attention
indicator) displays at the alert panel of the Products View or Hardware View.
An event code recorded at the director Event Log or the Embedded Web Server
event log.
•A Failed message associated with a FRU at the Embedded Web Server interface.
1
Was an event code 300, 301, 302, 303, 304, 305, 414, 420, 433, 440, 604, 605, 607,
805, 806, 807, 810, 811, 812, or 850 observed at the director Event Log (HAFM
server) or at the Embedded Web Server event log?
YES NO
Go to step 3.
2
Table 2–9 lists event codes, brief explanations of the codes, and associated steps that
describe fault isolation procedures.
Table 2–9: MAP 500: Event Codes
Event
Code Explanation Action
300 Cooling fan propeller failed. Go to step 5.
301 Cooling fan propeller failed. Go to step 5.
302 Cooling fan propeller failed. Go to step 5.
303 Cooling fan propeller failed. Go to step 5.
304 Cooling fan propeller failed. Go to step 5.
305 Cooling fan propeller failed. Go to step 5.
414 Backup CTP2 card failed. Go to step 7.