director 2/64 service manual

2–72 director 2/64 service manual
Diagnostics
10
Is fault isolation being performed at the HAFM server?
YES NO
Fault isolation is being performed at the Embedded Web Server interface. Go
to step 18.
11
Is a blinking red and yellow diamond (failed FRU indicator) overlaying a fan module
graphic at the Hardware View?
NO YES
A fan module failure is indicated. Go to step 5.
12
Is a blinking red and yellow diamond (failed FRU indicator) overlaying a CTP2 card
graphic at the Hardware View?
NO YES
A CTP2 card failure is indicated. Go to step 7.
13
Is a blinking red and yellow diamond (failed FRU indicator) overlaying an SBAR
assembly graphic at the Hardware View?
NO YES
An SBAR assembly failure is indicated. Go to step 9.
14
At the Hardware View, is a gray square displayed at the alert panel, a No Link
status displays at the Director 2/64 Status table and graphical FRUs are uninstalled?
YES NO
A green circle displays at the alert panel and the director is operational. Exit
MAP.