Diagnostics
10
Is fault isolation being performed at the HAFM server?
YES NO
↓ Fault isolation is being performed at the Embedded Web Server interface. Go
to step 18.
11
Is a blinking red and yellow diamond (failed FRU indicator) overlaying a fan module
graphic at the Hardware View?
NO YES
↓ A fan module failure is indicated. Go to step 5.
12
Is a blinking red and yellow diamond (failed FRU indicator) overlaying a CTP2 card
graphic at the Hardware View?
NO YES
↓ A CTP2 card failure is indicated. Go to step 7.
13
Is a blinking red and yellow diamond (failed FRU indicator) overlaying an SBAR
assembly graphic at the Hardware View?
NO YES
↓ An SBAR assembly failure is indicated. Go to step 9.
14
At the Hardware View, is a gray square displayed at the alert panel, a No Link
status displays at the Director 2/64 Status table and graphical FRUs are uninstalled?
YES NO
↓ A green circle displays at the alert panel and the director is operational. Exit
MAP.