director 2/64 service manual
2–76 director 2/64 service manual
Diagnostics
Does the Status field display a Failed message for either SBAR assembly?
NO YES
↓ An SBAR assembly failure is indicated. Go to step 9.
The director is operational. Exit MAP.
MAP 0600: UPM Card Failure and Link Incident Analysis
This MAP describes fault isolation for UPM cards, shortwave laser small form factor
pluggable (SFP) optical transceivers, and longwave laser SFP optical transceivers; and
for Fibre Channel link incidents. Failure indicators include:
• One or more amber LEDs on the UPM card illuminate.
• One or more emulated amber LEDs on a UPM card graphic at the Hardware
View illuminate.
• A blinking red and yellow diamond (failed FRU indicator) displays over a UPM
card graphic or a yellow triangle (attention indicator) displays at the alert panel of
the Products View, Hardware View, or Port Card View.
• An event code recorded at the Director 2/64 Event Log or the Embedded Web
Server event log.
• A port operational state message or a Failed message associated with a UPM card
at the Embedded Web Server interface.
• A link incident message recorded in the Link Incident Log or Port Properties
dialog box.
1
Was an event code 080, 504, 505, 506, 507, 512, 514, 800, 801, or 802 observed at the
director Event Log (HAFM server) or at the Embedded Web Server event log?
YES NO
↓Go to step 3.
2
Was an event code 581, 582, 583, 584, 585, or 586 observed at the console of an OSI
or FICON server attached to the director reporting the problem?
YES NO