director 2/64 service manual
director 2/64 service manual 2–77
Diagnostics
↓ Go to step 4.
3
Table 2–10 lists event codes, brief explanations of the codes, and associated steps that
describe fault isolation procedures.
4
Is fault isolation being performed at the director?
YES NO
Table 2–10: MAP 600: Event Codes
Event
Code Explanation Action
080 Unauthorized world-wide name. Go to step 23.
504 UPM card failure. Go to step 7.
505 UPM card revision not supported. Go to step 36.
506 Fibre Channel port failure. Go to step 7.
507 Loopback diagnostics port failure. Go to step 14.
512 SFP optical transceiver nonfatal error. Go to step 6.
514 SFP optical transceiver failure. Go to step 6.
581 Implicit incident. Go to step 29.
582 Bit error threshold exceeded. Go to step 29.
583 Loss of signal or loss of synchronization. Go to step 29.
584 Not operational primitive sequence received. Go to step 29.
585 Primitive sequence timeout. Go to.step 29.
586 Invalid primitive sequence received for current
link state.
Go to step 29.
800 High temperature warning (UPM card thermal
sensor).
Go to step 7.
801 Critically hot temperature warning (UPM card
thermal sensor).
Go to step 7.
802 UPM card shutdown due to thermal violation. Go to step 7.