director 2/64 service manual
director 2/64 service manual 2–81
Diagnostics
12
Inspect the port state and LED status for all ports with an attention indicator.
1. At the Port Card View, double-click the port graphic with the attention indicator.
The Port Properties dialog box displays.
2. Inspect the Operational State field at the Port Properties dialog box, and the
emulated green and amber LEDs adjacent to the port at the Port Card View.
3. Table 2–11 lists LED and port operational state combinations and associated MAP
0600 (or other) steps that describe fault isolation procedures.
13
A link incident may have occurred, but the LIN alerts option is not enabled for the port
and the attention indicator does not display.
Table 2–11: MAP 600: Port Operational and LED States
Operational State
Green
LED
Amber
LED Action
Offline Off Off Go to step 16.
Not Operational Off Off Go to step 16.
Testing Off Blinking Internal loopback
test in process.
Exit MAP.
Testing On Blinking External loopback
test in process.
Exit MAP.
Beaconing Off or On Blinking Go to step 17.
Invalid Attachment On Off Go to step 18.
Link Reset Off Off Go to step 28.
Link Incident Off Off Go to step 29.
Segmented E_Port On Off Go to MAP 0700:
Fabric, ISL, and
Segmented Port
Problem
Determination.